NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis. MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-1220-89M-DX6
Lab Sample ID 103233946
Filename F11228B_08
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPEE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 11/19/2001 Received 12/21/2001
CCal Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 03:10
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0038 0.0020 J 2,3,7,8-TCDF-13C 2.00 59
3 Total TCDF
2,3.7,8-TCDD
0.1100
ND
0.0020
0.0025 A
2,3,7,8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
2.00
2.00
69
58
57
Total TCDD 0.1200 0.0020 1,2,3,7,8-PeCDD-13C 2.00 70
3 1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
ND
ND
0.0100
0.0100
1,2,3,4,7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2,3,4,6,7.8-HxCDF-13C
2.00
2.00
2.00
70
68
69
Total PeCDF 0.0270 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 69
i ! 1,2,3,4,7.8-HxCDD-13C 2.00 95
■J 74
1,2,3,7,8-PeCDD ND 0.0100 1,2.3,6,7,8-HxCDD-13C 2.00
Total PeCDD 0.0840 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 72
1,2,3,4,7,8,9-HpCDF-13C 2,00 71
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 85
4
1,2,3,6.7.8-HxCDF ND 0.0100 OCDD-13C 4.00 64
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
3 Total HxCDF 0.0210 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3.6,7,8-HxCDD ND 0.0100
i 1,2,3,7,8,9-HxCDD
Total HxCDD
ND
0.0970
0.0100
0.0100
1,2,3,4,6,7.8-HpCDF 0.0260 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.0018 ng/m2
Total HpCDF 0.0390 0.0100 J (Using ITE Factors)
1,2,3,4,6.7,8-HpCDD 0.0600 0.0100
Total HpCDD 0.1200 0.0100
OCDF 0.0390 0.0200 J
OCDD 0.4900 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003474163
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000249279
OCR can misread numbers and units. Confirm readings against the page image before using them.