NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
2£;-ll Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: lO/27/Ol
ASBE£!TOS FIBER ..ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: .MIEEA Final Rule, EPA Federal Register (40 CFR, Part 76; , Vol. 51, No. 210, October 30, 1987
Samp]e Identification Analysis Parameters
Project/Site: New 5tuv\-esant H.5., 345 Chambers St., NY, NY TEN Sample No.: 5776 62380
Exterior &1 nterior of Building & Roof
Date Received: 10/26/Cl Grid Openings Analyzed;__4
Project Sample No.: 18 Average Grid Opening: 106.00 um
Air Volume ;952 1it^3 Total Area Analyzed :0^04 50 rTinT2
Filter Type: MCE 25 mn diam., Pore Size: 0.45 um .Analytical Sensitivity: .22.2 s/mm2
Effective .^rea: 3 8 5 mm2 0.0044 5/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Sing]e Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/tnin2 Struct/cc nom/rn3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000
Amphibole Asbestos 0 0 U 0 0 0 0.0 0.OOOC 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures 0 0 0.c 0.OOOC N/A
The e.stimated uncertainty of this analysis is 1 standard deviation
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC1OO_OO3473392
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248321
OCR can misread numbers and units. Confirm readings against the page image before using them.