NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 43%

Asbestos TEM analysis with SAED/EDS; project New Stuyvesant H.S., received 10/26/01.

NYC-WTC_000248312
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/27/01

ASBESTOS FIBER .kNALYSISBYTRANSMISSIONELECTRQNMICROSCOPYjTEM) With Fiber identification by Selected-Area Electron Diffraction (SAED! and Energy-Dispersive X-RAY Spectroscopy .EDS) Method; MERA Final Role, EE’A Federal Register !40 CFR, Part 163!, vol. 52, No, 213, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5775 62371 Exterior & Interior of Building & Roof Date Rectiived: 10/262C1 Grid Openings Analyzed:__4

Project Sample No.:_K Average Grid Opening: 105.00 urn

Air Volume !1928]jX^£ Total Area Analyzed: 0,0450 mm2

Filter Ty-pe: MCE 25 mm diem., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective' Area; 3 85 mm2 0.C044 s/c

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Strucc/irim2 Scruct/cc ngm/m3

Chrysotile Asbestos 0 0 C 0 0 C 0.0 0.0000 0

Amphibole Asbestos 0 0 c 0 0 c 0.0 0 . 0000 0

AmbiguouL' 0 0 0 0 0 0 0,0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 C 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0 0 0,0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis wa.s carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473383 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248312

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248312Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294007

TEM analysis report for New Stuyvesant H.S. site, Oct 2001.

Similar indexed content

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

NYC-WTC_000270429

Asbestos fiber analysis by TEM on New Stuyvesant High School exterior/interior samples, per AHERA procedures, received 10/15/01.

Similar indexed content

Compare copies and versions →