NYC 9/11 Public Portal Document
ATC Environmental, Inc,
104 East 25th Street
New York, New York 10010
N,Y,C, Board of Education Approved N,Y, State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectro.scopy (EDS')
Method: AHERA Final Rule, FPA Federal Register (40 CFR, Part tes), Vol. 52, No, 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Sihe; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5166 62333
Exterior & Interior of Building & Roof
Date Received; 10/2S/CI Grid Openings Analyzed:__ 4
Project Scimple No. ; 1 Average Grid Opening: 106,00 um
Air Volume: 1928 liters Total Area Analyzed: 0.0450 mm2
Filter Tyi) e : MCE 25 mm diam,, Pore Size: 0.45 urr. Analytical Sensitivity: ^2^2 sZmm2
Effective Area: 3 85 m.ml C.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct, Struct > = 5um Struct/mm2 Struct/cc nara/m3
Chrysotile Asbestos tD 0 0 0 0 0 0.0 O.GOOO 0
Amphibole Asbestos ID 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 o.ooco N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i,d, (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The T^nalysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Michael A, Gorycki, Ph,D, Michael A, Gorycki, Ph,D,
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473345
SUBJECT TO PROTECTIVE ORDER NO, 2, SEPT, 2008
NYC-WTC_000248278