NYC-WTC_000292757
TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis; New Stuyvesant HS, sample 5758-62157, received 10/24/01.
NYC-WTC_000274166OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy iEDS) Method: AlIERA Final Rule, EPA Federal Register (40 CFR, Part 763 ), Vol. 52, Ko. 210, October 30, 1967
Sample Identification Analysis Parameters
Project/Sit.e: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5758 - 62157 Exterior & Interior of Building & Roof Date Received: 1C/24/Q1 Grid Openings Analyzed:__ 4
Project Sample Nc. Average Grid Opening: 106.00 urn
Air Vclume': 1944 liters Total Area Analyzed: 0,0450 mm2
Filter Ty})e; MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity:22j.2 s2iI>IL2 Effective Area : 385rnr^ 0 . 0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATIOT Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >-5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Ambiguous 0 0 c 0 0 0 0.0 c.oooo 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003107267
NYC-WTC_000274166
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000292757
TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293901
TEM data with air volume and analysis parameters for building sample.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293853
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188708
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270885
TEM analysis; exterior/interior, sample 18.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270804
TEM asbestos analysis for New Stuyvesant High School, received 10/24/01.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188709
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270670
TEM analysis of asbestos fibers at New Stuyvesant H.S. with SAED/EDS, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270914
Asbestos fiber TEM analysis for New Stuyvesant High School, Oct 2001.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188481
Laboratory report detailing asbestos fiber analysis by TEM and EDS for exterior and interior building samples.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270805
TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000292757
TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293901
TEM data with air volume and analysis parameters for building sample.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293853
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188708
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270885
TEM analysis; exterior/interior, sample 18.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.
Similar indexed content
NYC-WTC_000270797
TEM asbestos fiber analysis for New Stuyvesant H.S. exterior and interior areas.
Similar indexed content
TEM data with air volume and analysis parameters for building sample.
Similar indexed content
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similar indexed content
Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.
Similar indexed content