NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

EPA NYC air/wipe sampling summary, Oct 2001

Machine-extracted title · confidence 56%

EPA memo summarizing asbestos air and wipe/water sampling results and locations.

NYC-WTC_000248077–000248078
Page image
Scanned page image, NYC-WTC_000248077
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency Air / Bulk / Wipe/ Water Sampling Situation Report Monday, October 1, 2001 (3:00 pm) Fixed Ambient Air Sampling Locations (Asbestos) NYC / ER (Sept 28, 12 noon - 12 midnight) o 6 of 17 samples were above the NYC reentry standard for PCM. All 17 samples were below the TEM standard. NYC / ER (Sept 29, 12 midnight - 12 noon) o 7 of 16 samples were above the NYC reentry standard for PCM. 2 of the 16 samples were above the TEM standard (Locations E and K). NJ (Sept 29, 9:45AM - Sept 30, 10:30AM) o All 4 samples were below both the PCM and TEM standards.

Landfill Air Sampling Locations Fresh Kills (Sept 29, 7:00AM - 7:00PM) - Asbestos o All 11 samples were below both the PCM and TEM standards.

Fresh Kills (Sept 28, 29) - Particulate Monitoring o Nothing of significance to report based on average daily concentrations. o No data collected on Sept. 27, 30, and October 1 due to weather conditions. Ambient Air Sampling Locations (Metals) NYC / ER (Sept 27) o Ten samples collected. o 1 sample exceeded the National Ambient Air Quality Standard (1.5 ug/m^ based on a 24 hour, 3 month period) for lead at Barclay/West Broadway, however does not exceed the NIOSH standard. o Lead level lower than sample previously taken at that location (and two other locations). o Chromium levels were identified at 9 locations above the EPA Removal Action guidance levels. However, all levels were below the removal action level adjusted to a 1 -year exposure duration and do not exceed the most conservative NIOSH chromium standard (1 ug/mQ. o Although the lead and chromium levels are elevated, they are not a short-term concern. o Regulatory standards and guidelines for lead and chromium are based on long-term exposure.

Ambient Air Sampling Locations (TAGA - volatile organics) NYC / ER (Sept 30) o Benzene exceeded OSHA TWA PEL (0.5 ppm) at two locations on the debris pile in the plume at ground level (across from Liberty/Greenwich).

CITY_DEP_WORBY_CANNATA_SUBP_000036291

NYC-WTC_000248077

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248077Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos air sampling, Sep 29, 2001

NYC-WTC_000340002

Earliest TEM confirmations showing some samples above AHERA at specified intersections in Financial District.

Similar indexed content

Compare copies and versions →