Asbestos air sampling, Sep 29, 2001

Machine-extracted title · confidence 42%

Earliest TEM confirmations showing some samples above AHERA at specified intersections in Financial District.

NYC-WTC_000340002–000340003
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I

U.S. Environmental Protection Agency Sampling Situation Report I Saturday, September 29,2001 (11:30 AM)

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept.26, 12:00 noon to 12:00 midnight) { O All 16 samples (including 1 duplicate) were below the OSHA PCM standard and were also below the NYC reentry standard. However confirmatory TEM analysis showed that 4 I of these 16 samples were above the AHERA standard (70S,'mnr). (Note: Sample I volumes collected were lower than the recommended volumes but were adjusted to determine if they exceeded established standards.)

o The four samples exceeding the AHERA standard had results of 163 s/mm2,118 s/mm2, 296 s/mm2, and 74 s/mm2 and corresponded to locations D (East End of Albany Street at Greenwich Street), F (Northern media strip of Vesey and West Street), K (West Street and Albany Street in median strip) andQ (Barclay and West Street (center island), respectively. All these samples are within the immediately impacted area.

Fixed Ambient Air Sampling Locations (Asbestos) I NYC / ER (Sept.28, 12:00 midnight - 12:00 noon) O All 17 samples (including 1 duplicate) were below the OSHA PCM standard and were also below the NYC reentry standard. No samples exceeded the AHERA standard of 70S/mm2. I New Jersey O Sept 26 - all 4 samples were below the established standards.

NYC Bulk/Dust Samples (Landfill)

Eight samples taken on Sept. 28 at the landfill were non-detect for asbestos.

Landfill Air Sampling locations (Asbestos)

11 air samples taken on Sept. 26 (8:00 AM - 6:00 PM) were below the established standards for all the methods analyzed. 11 air samples taken on Sept. 27 (7:30 AM - 6:30 PM) were below the established standards for all the methods analyzed. I 11 air samples taken on Sept. 26-27 (6:30 PM on Sept .26 - 7:30 AM on Sept .27) were below the established standards for all the methods analyzed.

Direct Reading Instruments

Nothing of significance identified.

NYC Ambient Water Sampling

SI The seven water samples taken on Sept.25 showed no levels above the established Drinking Water MCL for asbestos of 7 MFL (million of fibers per liter). J

CITY_21MC100_007222555

NYC-WTC_000340002

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340002Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →