SECTION FOUR Regiilatorv Agency File Review UH*

• New York State DEC Spill Report Form - 90 Worth Street reported a spill on April 25, 1996. Apparently, an unknown large quantity of petroleum product was dumped in the street. The New York City Hazmat Unit responded to the scene; • New York State DEC Spill Report Form - A No. 2 Fuel Oil spill was reported on Januaiy 19, 1999 at 85 Worth Street. The dome cover of a truck leaked onto the street. The New York City FD responded to the call; • New York State DEC Spill Report Form - A fuel oil spill was reported at 125 Worth Street on June 21, 2001. The spill cause was a tank failure. This spill was described previously in this report. State Environmental Services was at the location on June 21, 2001 to perform tightness tests on two 19,000-gallon capacity fuel oil tanks. Upon their arrival, they encountered a fuel spill and notified the New York State DEC. Oil was found on the boiler room floor and on the top of the tank containment structure. The basement sump had several hundred gallons of fuel oil floating on approximately 1,500 gallons of water. The building engineer stated that the boilers have not been used in five years and the spill occurred approximately one year prior. The New York State DEC required the New York Citywide Administrative Services to do additional investigation regarding the spill. The New York State DEC required that the groundwater flow direction be determined, test borings be advanced in the vault and in the basement, and the reason the oil was in the boiler room determined. An Investigation Summary and Remedial Plan dated October 2001 was prepared for the site. Three test borings were advanced and finished as monitoring wells. A total of five soil samples were collected from the three test borings and groundwater samples were collected from the three monitoring wells. The soil samples were analyzed for gasoline-related volatile organic compounds (VOCs), including methyl tert-butyl ether (MTBE) and naphthalene, using USEPA Method 8021 and for diesel-related semi­ volatile organic compounds (SVOCs) using USEPA Method 8270. No exceedances of TAGM No. 4046 guidance values for VOCs were observed in the soil samples collected from monitoring well nos. MW-3, MW-4 and MW-5. Exceedances of TAGM No. 4046 guidance values for SVOCs were observed in soil samples from monitoring well nos. MW-3 and MW-4. Groundwater samples were analyzed for gasoline and diesel-related compounds using USEPA Methods 8021 and 8270. No exceedances of New York State DEC groundwater quality criteria for VOCs were observed; however, slight exceedances for SVOCs at monitoring well nos. MW-4 and MW-5 were observed. Total SVOC concentrations were 8 parts per billion (ppb) and 25 ppb, respectively, in the samples collected from monitoring well nos. MW-4 and MW-5. No floating product was observed in the monitoring wells. The report states that the site conditions indicate that most of the fuel oil spill was contained within the tank vault and boiler room. Therefore, service disruptions and potential hazards involved with additional investigations surrounding the building are not warranted. The report recommended that the tanks should be cleaned and formally closed by filling with concrete or removing. The New York State DEC stated on February 26, 2002 that, to ensure the delineation of the entire plume (horizontally as well as vertically), groundwater flow direction must be ascertained through the installation of MM

URS Corporation l:\Projects\Hollers\WReport.<locM4-MAV-03«WYN 4-9

CONFIDENTIAL INSURANCE INFORMATION, CITY_2IMCl00_013273683 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000247110

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000247110Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000137900

Archival folder label for Department of Environmental Protection biweekly reports related to World Trade Center activities from 2000 to 2001.

Similar indexed content

Compare copies and versions →