NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Summary of asbestos sampling, 70 Battery Place

Machine-extracted title · confidence 33%

November 2001 asbestos sampling at a NYC building with fiber results and analysis.

NYC-WTC_000247025–000247027
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

PEB-0S-2002 17:24 71S 391 2385 718 391 2385 P.06Z06

Summary ofAsbestos Sampling Results Page 3 of 3 Add'ess: 70 Battery Place Date sampled: November J9, 2001

(cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content as a percent. PLM is used for regulatory purposes for dust samples.

Results of Polarized Light Microscopy (PLM) testing of dust at 70 Battery Place, Nov. 19,2001 Area Sampled Outside Outside* Common Residence 1 Residence 2 Twin '

Sample Numbers SA-O-10 SA-O-X-10* VA-C-10 VA-Rl-10 VA-R2-10

k'/.'F Asbestos fibers (%) None None None None None Detected Detected Detected Detected Detected ssss::^^=ss \jU\ \ * Denotes a second sample taken in the same location for quality' control purposes.

Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust samples that showed asbestos content by PLM as less than 1%. TEM analysis is very specific, detect smaller fibers of asbestos, and is sensitive to less interference. This analysis was done A \tN confirm the PLM findings of no asbestos shown above. However, TEM analysis is not used ' for regulatory purposes for dust samples.

\ „ Results of Transmission Electron Microscopy (TEM) testing of dust at 70 Battery Place, (A Nov 19,2001 //--------------------------------------------------------------------------------- ------------------------------------------------------ I Area Sampled Common Residence 1 Residence 2 Outside Outside* Sample Numbers SA-O-10 SA-O-X-10* VA-C-10 VA-RMO VA-R2-10 Asbestos fibers (%) None < 1% 1.5 % None Detected None Detected Detected < 1 %*• (I , , '*■*■■*—■■ » ■ ■

* Denotes a second sample taken in the same location. ’* Denotes re-analysis of original sample for quality control purposes.

TOTAL P.*06

CITY_21MC1OO_O13398724

NYC-WTC_000247027

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000247027Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000319462

Air test results for asbestos at 70 Battery Place; multiple indoor locations sampled.

Similar indexed content

Compare copies and versions →