NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Asbestos sampling results, 70 Battery Place, Nov 2001

Machine-extracted title · confidence 95%

Summary of asbestos air and dust sampling results conducted at 70 Battery Place on November 19, 2001.

NYC-WTC_000238036–000238038
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

718 331 2385 ®P®.0®6/«6

y

Svfnmary ofAsbestos Sampling Results Page $0/3 Address: 70 Battery P!ac£ Date sampled: Ncfvember J9, 200/

(cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content as a percent. PLM is used for regulatory purposes for dust samples.

Results of Polarized Light Microscopy (PLM) testing of dust at 70 Battery Place, Nov. 19,2001 Area Sampled = Outside Outside* CornmoB Residence 1 Residence 2 Sample Numbers SA-O-10 SA-O-X-10* VA-C-10 VA-JO-10 VA-R2-10

kAshestos fibers (%) None None None None None Detected Detected Detected Detected Detected * Desotss a second sample taken in the same location ibr quality control puiposes.

Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust . samples that showed asbestos content by PLM as leas than 1%, TEM analysis is very specific, //^ \ can delect smElIer fibers of asbestos, and is sensitive to less imeiference. This analysis was done \ \ \ PLM findings of no asbestos shown above. However, TEM analysis is not used ' for regulatory purposes for dust samples.

lA \ V Results of Transmission Electron Microscopy (TEM) testing of dust at 70 Battery Place, Nov 19. 2001 .............. .................— Area Sampled Outside Outside* Common Residence 1 Residence 2 Sample Nxtfnbcrs SA-O-10 SA-O-X-10* VA-C-10 VA-RMO VA-R2-10 Asbestos fibers (%) None < 1% 1.5 % None Detected None Detected Detected < 1 %•• * Denotes a second sample taken in the same locjrioii. ** Denotes re-analysis of original sample for quality control purposes.

TOTAL P.‘06 NYC-WTC_000238038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000238038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000319462

Air test results for asbestos at 70 Battery Place; multiple indoor locations sampled.

Similar indexed content

Compare copies and versions →