Asbestos sampling results, 70 Battery Place, Nov 2001

Machine-extracted title · confidence 95%

Summary of asbestos air and dust sampling results conducted at 70 Battery Place on November 19, 2001.

NYC-WTC_000238039–000238041
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 02/0^6/2002 20:57 FAX 12125180469 BOVIS/WTC FEB-06-2002 17=24 7iS 391 23S5 0006 718 331 2385 F.06/06

Svramary ofAsbestos Sampling Results Page 3 of 3 Address: 70 Battery Place Date sampled: November 19, 2001

(cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content as a percent. PLM is used for regulatory purposes for dust samples.

Results of Polarized, Light Microscopy (KLM) testing of dust at 70 Battery Place, Nov. 19,2001 Area Sampled Outside Outside* Common Residence 1 Residence! ==ss=s£a!SMc±S=s; SSWBOftB: =SaBli«===5= «aiB^=S= - ■ ' ■■■— I

\ Sample Numbers SA-O-10 SA-O-X-10* VA-C-10 VA-R.3-10 VA-R2-10

Y Asbestos fibers (%) None None Detected Detected None Detected None Detected None Detected Denotss a second sample taken in the same iocatixHi for quality control purposes.

Asbestos in dust as deterrnined by TEM analysis! TEM analysis was conducted on all dust samples that showed asbestos content by PLM as leas than 1%. TEM analysis is very specific, can detect smaller fibers of asbestos, and is sensitive to less interference. This analysis was done to confirm the PLM findings of no asbestos shown above. However, TEM analysis is not used for regulatory purposes for dust samples.

Results of Transmission Electron Microscopy (TEM) testing of dust at 70 Battery Place, Nov 19,2001 : — MH mb ........ Area Sampled Outside Outside* Common Residence 1 Residence 2 Sample Numbers SA-O-10 SA-O-X-IO’ VA-C-10 VA-RMO VA-R2-10 Asbestos fibers (%) None < 1% 1.5 % None Detected None Detected Detected ___________________ ________ ___________ < 1 %** * Denotes a second sample taken in the same locatbn. ” Denotes re-analysis of original sample for quality control purposes.

T'afAL p.‘06

NYC-WTC_000238041

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000238041Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000319462

Air test results for asbestos at 70 Battery Place; multiple indoor locations sampled.

Similar indexed content

Compare copies and versions →