NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM TEM, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 28%

TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.

NYC-WTC_000244754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street- New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/23/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS; Method: ?JIER.A Final Rule, 3PA Federal Register (40 CFR, Part 7635, Vol. 52, No. 210, October 30, 1987

Sample Identification Analys2^s^a^amet^rs

Proj ect/Site; New StuxAresant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5739 61937 E?:terior Interior of Building & Roof Date Received;^;0222^^ Grid Openings Analyzed:__ 4

Project Sample No.:^ Average Grid Opening: 106.00 um

Air VoluTT.e : 1928 1 iters Total Area Analyzed ;^^,0£^0 rnm2

Filter Type: MCE 25 mm diau., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/nuT.2 Effective Area: 385 mm2 0.0044 5/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = Bum Struct/miri2 Struct/cc ngm/rr,3

Chrysotile Asbestos 0 0 0 c 0 0 0.0 0.oooc 0

Amphibole A.sbestos 0 0 0 0 0 0 0.0 o.oooc 0

Ambiguous 0 0 0 0 0 0 0.0 0 . oooc c

Total asbdstos (includes anbiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Totals (All Structures: 0 0 0. 0 0.0000 N/A Ths estimated uncertainty cd this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by.-

Roman Peysakhcv Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470303

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244754

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244754Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000244731

TEM SAED/EDS; exterior & interior of building; sample 5737; received 10/21/01.

Similar indexed content

Compare copies and versions →