ATC Environmental, Inc. 104 East 25th Street. New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/21/01

ASBESTOS FIBER ZiNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERJi Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1887

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5735 61717 Various Siten Inside and Outside the Building Date Received: 10/20/01 Grid Openings Analyzed:_ 4

Project Sample No.: 3 Average Grid Opening: 106.00 um

Air Volume: 1944 liters Total Area Analyzed :0^M.5p mm2

Filter Tviie ; MCE 25 mm di an.. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area; 385 mm2 0.0044 s/c:

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single: Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/tn3

Chrysotil(: Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 C.0 C . 0000 0

Ambiguous 0 c 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) c 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 c 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimeited uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbe.stos Type: None detected

The /analysis was carried cut in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO347O21O SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244672

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244672Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293690

TEM asbestos analysis of samples from New Stuyvesant High School, with SAED/EDS details.

Similar indexed content

NYC-WTC_000293453

TEM asbestos analysis of exterior and interior air samples from New Stuyvesant H.S. performed 10/01.

Similar indexed content

NYC-WTC_000270884

TEM analysis; exterior & interior, sample 17.

Similar indexed content

Compare copies and versions →