Asbestos fiber analysis by TEM and SAED/EDS for a project site at New Stuyvesant High School, received Oct 18, 2001.

NYC-WTC_000244613
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 ASBESTOS FIBER ASfALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Pibe:r Identification oy Selected-Area Electron Diffraction (SAEDj and Energy-Dispersive X-RAY Spectroscopy iED.Si Method: AHE-Vi Final Rule, i3PA Federal Register (40 CFR, Part 763i, Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/ Site: New .Stuyvesanl H.E., 345 Chambers St., NY, NY TEM Sample No.; 5725 61652 Exterior Interior of Building & Roof Date Received: 10/18/01 Grid Openings Analyzed:__ 4

Project Sample No.: 20 Average Grid Opening: 106.00 urn

Air Volume: 1928 liters Total Area Analyzed : m 045 0 mm2

Filter Ty^^e : RICE 25 mm diaru , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/miiiG Effective Area: 385 mmG 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single' Matrix Total. Struct. Filter Air Fiber! EundO^es Clusbers Struct^Struct > = 5um Struct/mm2 Struct/cc nam/m3

Chrysotile /asbestos C 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c

Ambiguous 0 0 0 0 0 0 0.0 0.0000 c

Total asbestos (includes anbiguous structures) 0 c 0.0 0 . 0000 0 Non-Asbest.os 0 0 0 0 0 c 0.0 0.0000 N/A No Idsntij;icdtion 0 0 0 0 0 0 0 . 0 0.0000 N/A

Totals (All Structures) 0 0 C.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Jmalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Michael A. Gcrycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO347O136 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244613

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244613Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000274155

TEM asbestos analysis; building exterior/interior, sample 5758, received 10/24/01.

Similar indexed content

NYC-WTC_000274122

TEM analysis of asbestos fibers, SAED/EDS, New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →