NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos fiber TEM analysis report, Oct 8 2001

Machine-extracted title · confidence 95%

Air sampling results from the exterior of a high school analyzing asbestos fibers using transmission electron microscopy.

NYC-WTC_000176403
Page image
Scanned page image, NYC-WTC_000176403
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/08/01 ASBESTOS FIBER iUlALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibe;r Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscooy (EDS] Method; AHERA Final Rule, SPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1587

Sample TdenCificacipn Analysis Parameters

Project/Site: New Stu-\n^ssant H.S., 345 Chambers 5t. , NY, NY TEM Sample No.: 5635 60S70 Exterior of 'juilding & Roof Date Received: 10/08/01 Grid Openings Analyzed:__ 4

Project Sample No . :NSHA2^H&F^l 0/.82^ Average Grid Opening: 106.00 um

Air Volume: 1R59 liters; Total Area Analyzed :0^.04Jj0 m2^

Filter Type: MCE 25 mm diar-.Pore Size: 0.45 um Analytical Sensitivity: 2 2.2 s/miT.2 Effective Aren ; 385 miTi2 C.9045 s/cc

FIBROUS PARTICULATES TkNALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fiber/; Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ncrm/m3

Chrysotile Asbestos 0 0 0 C 0 0 0.0 0.0000 0

Amphibole Ash>estos 0 0 0 0 0 0 o.c 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 C . 0000 0

Total asb'2stos (includes ambiguous structures] 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/fi No Identification 0 0 0 0 0 0 0.0 O.OOOG N/A

Totals (All Structures' 0 0 0.0 O.OOOC N/A The estimated uncertainty uf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

An.alyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO3469852 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000176403

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000176403Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →