NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10875 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED' and Energy-Disper.sive X-RAY Spectroscopy (EDS) Method: ^HERA Final Rule, .3P7i Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Prcjert/Site: New Stuy\>-esanc H.S., 345 Chambers St., NY, NY TEM Sample No.: 5725 61648 Exterior £4 Interior of Building & Roof Date Received: lO/LS/Ol Grid Openings Analyzed;__4

Project. Sample No. : 16 Average Grid Opening

Air Vo1ume: 1920 liters Total Area Analyzed: 0,0450 mm2

Filter Type: MCE 25 mm dram.. Pore Size: 0.45 um Analytical Sensitivity:22;2 s/mm2 Effective Aren :385nim2 C.0CJ45 s/cc

FIBROUS PARTICULATES /ANALYZED Number Observed CONCENTRATION Total Stngle Matrix Total. Struct. Filter Air Fibers Pundies Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nani/m3

Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Amphibole Asbestos C 0 0 0 0 0 0. 0 0.0000 0

Ambiguous 0 Q 0 0 0 0 0.0 0.0000

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0 c 0.0 0 . 0000 N/A

Totals (All Structures) 0 C C. 0 0.0000 N/A The estimeited uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Aneilyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470132 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244609

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244609Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000177638

Laboratory report for asbestos fiber analysis by TEM at New Stuyvesant High School received on October 28, 2001.

Similar indexed content

NYC-WTC_000293935

TEM analysis results for air samples at New Stuyvesant HS, exterior and interior, 10/25/01.

Similar indexed content

NYC-WTC_000248313

Asbestos TEM analysis by SAED/EDS for New Stuyvesant H.S.; received 10/26/01.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

Compare copies and versions →