TEM analysis, NSHS-EIR-10/17-9

Machine-extracted title · confidence 38%

TEM analysis details for NSHS EIR, Oct 2001.

NYC-WTC_000244580
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/18/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With ?ibe;r Identification by Sslected-Area Electron Diffraction iSAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHER7\ Final Rula. GPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample identification Analysis Parameters

Project/Site: New Stuyvesani F.S., 345 Chambers St., NY, NY TEM Sample No.: 5715 61542 Exterior S- Interior of Building jc Roof Date Received: Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-SlR-lC/17-io Average Grid Opening :

Air Velum';: 1908 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diari., Fore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Aree : 365 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total S j ngl€- Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ■> = 5um Struct /inm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 C 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 c 0 0.0 0 . 0000 0

Total asbestos iincludes arrbiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0.0 Cl . 0 0 0 0 K/A No Identilication 0 0 0 0 0 C.0 0.0000 N/A

Totals (All Structures) 0 0 C.O 0.0000 N/A The escinuited uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Anai lyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470102 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244580

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244580Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244725

TEM analysis by SAED/EDS, exterior & interior of building; sample 5737, received 10/21/01.

Similar indexed content

NYC-WTC_000244758

TEM analysis: exterior & interior of building; sample 5739; opening and air volume data.

Similar indexed content

NYC-WTC_000293522

TEM analysis of exterior/interior of NSHS building, Oct 2001.

Similar indexed content

Compare copies and versions →