ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/10/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDSj Method; AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987

Sample Identification AnalvsisParamet^rs

Froj ect/Site: New Stuyvesant H.S., 34 5 Chantbers St., NY, NY TEM Sample Nc.: 5662 60801 Exterior & Interior of Building & Roof Date Received: 10/10/01 Grid Openings Analyzed;__ 4

Project Sample No.: NSHS-EIR-10/10-02 Average Grid Opening: 106.00 um

Air Volume :1899jJ^ters Total Area Analyzed: 0,04 5 0 rnm2

Filter Type: MCE 25 mm diam., Fore Size: C.45 um Analytical Sensitivity; 22.2 s/mm2 Effective Area; 385rnrr^ 0■0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct. >=5un Struct/mm2 Struct/cc nqni/ni3

Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures} 0 C 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A Nc Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O82O84

NYC-WTC_000293446

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293446Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270486

TEM analysis of exterior/interior of New Stuyvesant HS; AHERA method.

Similar indexed content

NYC-WTC_000293522

TEM analysis of exterior/interior of NSHS building, Oct 2001.

Similar indexed content

NYC-WTC_000293526

TEM asbestos analysis parameters for NSHS site, Oct 2001.

Similar indexed content

NYC-WTC_000293521

TEM asbestos identification with diffraction/EDS for NSHS, Received 10/14/01.

Similar indexed content

Compare copies and versions →