ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/15/01

ASBESTOS FIBER J'iNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED; and Energy-Dispersive X-RAY Spectroscepy (EDS; Meched: AHERiX Final Rule GPA Federal Register (40 CFR, Part 7631, Vol. 52, No. 21C, October 30, 1967

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant. H.S., 345 Chambers St., NY, NY TEM Sample No.: 5691 61C73 Exterior & Interior of Building & Roof Date Received; 10/lh>/0- Grid Openings Analyzed:__4

Project Sample No . : Average Grid Opening: 106.00 um

Air Volum?: 1690 liters Total Area Analyzed: 0.0450 mm2

Filter Tyi^e : MCE 25 mm diaTs.. , Fere Size: 0.45 um Analytical Sensitivity: 22,2 s/mm2 Effective Aret: 385mm2 Q.0045 5/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct /nim2 Struct/cc ngm/m3

Chrysotile; Asbestos 0 0 0 0 0 0.0 o.cooo

Amphibole Asbestos C 0 0 0 0 0 0.0 0.GOOD 0

Ambiguous 0 0 0 0 0 0 0.0 O.OCOO 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/.^

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty ci chts analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphit'Ole Asbestos Type: None detected

The A.nalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470009 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244494

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244494Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270814

TEM asbestos analysis with SAED/EDS, New Stuyvesant High School.

Similar indexed content

NYC-WTC_000270764

TEM asbestos analysis with SAED/EDS; sample 5748-62071, exterior/interior.

Similar indexed content

NYC-WTC_000270926

TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293474

Asbestos fiber TEM analysis of bulk samples from New Stuyvesant High School exterior and interior areas.

Similar indexed content

NYC-WTC_000294009

TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →