NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/13/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber IdentificatLon ny Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDSl
Method: AhERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967
Sample Ident-ficaciori Analysis Parameters
Proj ect./Site ; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5676 61047
Exterior & Irterior of Building & Roof
Date Received ;1O/13ZC2 Grid Openings Analyzed:__ 4
Project Sample No.: NSRS-EIR-10/12-05 Average Grid Opening: 106.00 um
Air Volume:1917]d^^rs Total Area Analyzed-0^045 0 mm2
Filter Tyjie: MCE 25 mrr, dian.. , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Area; 385 mm2 D.004S £/cc
FIBROCS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >-5uit Struct/mm2 Struct/cc ngm/rr.3
Chrysotile Asbestos 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 o.c 0.0000 0
Total asbestos (includes amoiguous structures) c 0 0.0 0.0000 0
Non-Asbescos 0 0 0 c 0 o.c • 0.0000 N/A
No Identification 0 0 0 0 0 o.c 0.0000 N/A
Totals (All Structures) 0 0 o.c 0 . C000 N/A
The estimc.ted uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Imalysis was carried out in accordance with the approved TEM method.
This laboratory as in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by;
Marek Peysakhov Michael A. Gorycki, Ph.0.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003469957
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244450