OSHA SAMPLING RESULTS SUMMARY AS OF 11717
Asbestos; A total of 652 air monitoring samples for asbestos have been taken. From 9/13
-9/21, 177 samples were taken in the financial district. They were taken on
OSHA personnel as they walked within certain predetermined zones. Results
revealed asbestos concentrations ranging from ND (none detected) to .037 f/cc.,
well below OSHA’s permissible exposure limit (PEL) of .1 f/cc.
After 9/21, sampling focused on the rubble pile and those workers working on
or immediately next to it. 63 of the samples analyzed exceeded OSHA’s limit
viaPCM analysis. However, upon further analysis using discriminating counting
methods and/or TEM analysis, the number of asbestos fibers found dropped
dramatically to below detectable levels or well below .1 free.
Carbon Monoxide: A total of 47 personal samples of workers on ±e rubble pile showed results
ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm
permissible exposure limit.
Noise: OSHA has been conductingnoise monitoring in therubble pile. Twelve personal
samples have been conducted on employees performing (or working near)
various operations such as jack hammering. Employee’s exposure to the noise
range from 80.6 dBA to 89 dBA. OSHA’s permissible noise exposure for
construction is 90 dBA
Respirable
Silica: The overwhelming majority of the 247 silica samples show no detectable levels
of airborne silica. However, the highest sample result was approximately nine
times the OSHA limit on pre-drillers working on the bathtub wall. The only
otber exposures that appear to be over the PEL level were approximately twice
the OSHA limit. These two exposures occurred during: 1) rubble removal and
loading operations near the Winter Garden; and 2) during the breaking up of
concrete in the pit. All of the work areas where apparent oyerexposures to silica
occurred were in the rubble pile; an area where OSHA contmues to encourage
die use of respiratory protection.
Volatile Organic
Compounds; OSHA has taken 431 samples for (VOCs) such as acetaldehyde, acrolein,
. acrylonitrile, benzene, 2-butanone, carboftirans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde, Freon R-22 (chlorodiflouromethane), hexone,
isocyanates (e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene, 1-3
butadiene, trichloroethylene, vinyl chloride, and xylene. Screening samples
initially showed elevated levels of some organic chemicals resulting from the
fires burning in the rubble pile. Subsequent personal and area samples show
w^orker exposure levels to be below OSHA limits.' However, one personal
sample result for benzene was found to be at the 8-hr, OSHA Allowable Limit
concentration of 1 ppm. This was found on a backhoe operator moving debris.
See information below for polynuclear aromatics. Freon R-22, phosgene and
. dioxin.