Minimum contractor requirements for asbestos removal, 100 Church Street

Machine-extracted title · confidence 38%

Contractor COC outlines asbestos-containing dust removal on selected floors of 100 Church Street.

NYC-WTC_000243907–000243914
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SEP-28-01 FRI 03:34 PM RHKP FAX NO. P. 08/10 SEP”?6'“01 TRI 02:36 PN "ANBIENT GROUP INC FAX NO. 212 768 1540 h UB

MlNiMOM CONTRACTOR REQUIREMENTS accordance with applicable regulatory requirements. Filter all water used for showering and cleaning equ^ment through a 5-inIcton filtration system. Dispose of waler in the sanitary sewer system. 5.6 Provide temporary connection to existing building utilities or provide temporary facilities as required or as necessary to Carry out the Work. 6,0 NEGATIVE PRESSURE SYSTEM (IF USED) 6.1 If needed provide fully operational diminished air equipment to be used as needed in each work area while cleanup procedures ace in affect. The exhaust of the negative pressure system shall be directed outside of the building. Allow exhaust units to run until completion of work area cleanup. 6.5 Wlien a final inspection and tlie results of final air tests indicate that the area has been decontamlnafed, HEPA filtration system shall be removed from the work area in conjunction with the isolation barriers. 7.0 ^'WctlpN NOT USED

8.0 WORKER DECONTAMINATION PROCEDURES 8.1 Require all workers to adhere to the following personal deconiamination procedures whenever they leave the work area; a) When exiting area, remove outer layer of disposable coveralls, disposable head covers, and disposable footwear covers or boots in the first airlock at ftc exit of the tent enclosuie.

b) Stilt wearing respirators and remaining layer of disposable covering, proceed to remote shower unit and follow procedures as outlined for worker decontamination. 9.0 ASBESTOS REMOVAL 9.1 All horizontal surfaces within each respective work shall first be cleaned wJtli a HEPA vacuum followed by wet wiping with amended waler. When dry the area shall ba cleaned again using a HEPA filtered vacuum. 9.2 All itcm.s not to be discarded shall be cleaned and decontaminated and left in-place. Coordinate with Tenant Representative prior to discarding any items that cannot be decontamiristcd. <9.3 In areas where clotliing items are present, decontaminate tire item by first using a HEPA vacuum, followed by wet wiping and followed again by HEPA vacuum after die item has dried. 9,4 All non-poious personal items on work desks slwll be HEPA vacuumed, wet wiped and again Hep A vacuum. Place all items desk. AH porous personal items (suit case, purse, shoes, etc.) shall bo HEPA vacuumed, wet wiped and again HEPA vacuumed. Place in EWaVAL OF ACM 1>UST fAdEe ZARRe^ StUerti Fiam/Afem too Church Strttf

CITY_21 MCI 00_014587391 NYC-WTC_000243912

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243912Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000416762

Contract specs for abatement of asbestos-containing materials at Police Academy.

Similar indexed content

Compare copies and versions →