NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Stuyvesant High School indoor air study, 2002

Machine-extracted title · confidence 39%

Executive summary of DOH BOE indoor air study at SHS; sample results referenced.

NYC-WTC_000243060–000243095
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Stuyvesant Analysis Final Draft: For Internal NYC DOH Only, 2/8/2002, 10:44 AM

pollutants over the period of the school day since instantaneous measurements might represent the maximum level of the pollutant over an 8- hour period or the minimum level of that pollutant.

Further, there are no federal or state regulatory standards for CO2 or PM2.5 for non- occupational indoor environments. Currently, the only guidelines available for CO2 are the ASHRAE’ recommended guidelines for indoor CO2 in an non-industrial indoor environment. ASHRAE recommends that indoor CO2 be less than 700 ppm above background, outdoor levels, but does not state whether these guidelines should be compared to instantaneous values or averaged values of CO2. However, it is common practice to compare measurements obtained from instantaneous measurements to this guideline. It is important to note that levels slightly above the recommended level do not necessarily pose a health risk, but rather are useful for evaluating a ventilation system in an occupied building. NPAAQS'* are only available for outdoor PM2.5. Currently there are no available standards for indoor PM2.5. The current NPAAQS recommend that outdoor PM2.5 be less than 65 pg/m’ (a 24 hour averaged figure) for the general population. However, the EPA recommends a level of 40 pg/m’ (a 24 hour averaged figure) for sensitive populations. Comparing instantaneous samples such as those indoor samples collected by ATC with outdoor standards averaged over 24 hours is not a valid comparison. Therefore, the results of the analysis utilizing this instantaneous sample data must be viewed with caution.

Finally, the analyses performed represent only preliminary assessments and were not meant to be exhaustive in nature. The Specific Aims, Methods and Results for each analysis are presented separately. The Discussion section at the end of this report will encompass a discussion of all three analyses.

Part I: Comparison Between Years Within SHS

Specific Aims

A. To determine whether there has been an appreciable change in the average daily rate of headache, respiratory, eye, throat, skin and injury complaints reported to the Health Aide office by SHS students in October and November 2001 compared to October in 1998,1999 and 2000.

B. To determine whether there has been an appreciable change in the average daily attendance rates in October and November 2001 compared to the similar time periods in October and November 1998, 1999 and 2000.

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). ‘’us Environmental Protection Agency. National Primary Ambient-Air (Quality Standard

6

NYC-WTC_000243065

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243065Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000245464

Permit application unrelated excerpt; contains mayoral report and NYC identifiers; likely overarching documents for school-related permit.

Similar indexed content

NYC-WTC_000277292

Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.

Similar indexed content

NYC-WTC_000138069

Archival folder label for Health Department biweekly reports related to World Trade Center activities from 2000 to 2001.

Similar indexed content

Compare copies and versions →