Stuyvesant High School indoor air study, 2002

Machine-extracted title · confidence 39%

Executive summary of DOH BOE indoor air study at SHS; sample results referenced.

NYC-WTC_000243060–000243095
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Stuyvesant Analysis Final Draft: For Internal NYC DOH Only, 2/8/2002, 10:44 AM

in an overestimate of the rate of complaints because of the presence of a doctor and nurse at SHS in October and November 2001. Further, the students’ return to SHS may have evoked painful memories of the day of the attack causing emotional and psychosocial stress manifesting as somatic complaints. The emotional and psychosocial stress may have been made more acute given the proximity of the school to recovery and construction activities that also may have resulted in increased visits to the SHS health office independently of any effect of air quality.

The attendance figures utilized in this analysis include long-term absences (LTAs). LTAs may include students who have either withdrawn from the school without notifying school personnel or have transferred to other schools but remain on the attendance rolls. Therefore, the number of students present on any given day is an estimate for that day and not an exact figure. The presence of LTAs in the enrollment and attendance figures would artifactually decrease attendance rates but would not impact the number of students present. Any relative decline in 2001 compared to prior years could be the result of an increase in students transferring out of Stuyvesant because of the traumatic nature of the events on September 11, rather than an actual decline in attendance. Finally, attendance and enrollment figures in 2001 are updated as necessary to reflect new information received by the school. Therefore, the numbers utilized for these analyses represent the most recent estimates of daily enrollment and attendance figures.

In addition, typically in the fall, rates of respiratory, including asthma increase due to allergies, flu and other viral infections. Moreover, there can be substantial year-to- year variation in the prevalence of respiratory and other illness irrespective of air quality differences between 2001 and prior years.

In the within SHS analysis an assumption is that there is no significant difference among the student populations in any given year, an assumption that may in fact not be valid. The “comparison with other high schools” assumes that SHS, BHSS and BTHS student populations are more similar to each other than they are different which, in fact, may not be the case. Since all three high schools are specialized high schools, some students attending BTSS and BHSS may, in fact, live in the area surrounding the WTC site. The comparison to the non-competitive high schools assumes that if there is an increased rate of complaints at SHS due to poor air quality that Seward Park and Murray Bergtram may also see a similar increase. However, neither school is located as near to the WTC site as SHS and the student populations are quite dissimilar in that, traditionally, their attendance rates in general are much lower than that of SHS.

Limitations of the Air Quality Analysis The third analysis which examines the correlation between daily rate of student visits/ complaints and air quality also has several limitations. For one, the consultants performed instantaneous sampling in different rooms or areas each day rather than utilizing a sampling plan that would provide a representative sample of rooms or areas in the SHS. In addition, though instantaneous samples provide real time data on PM2.5 and CO2, this type of sampling may not provide a valid estimate of exposure to these

5

NYC-WTC_000243064

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243064Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000245464

Permit application unrelated excerpt; contains mayoral report and NYC identifiers; likely overarching documents for school-related permit.

Similar indexed content

NYC-WTC_000277292

Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.

Similar indexed content

NYC-WTC_000138069

Archival folder label for Health Department biweekly reports related to World Trade Center activities from 2000 to 2001.

Similar indexed content

Compare copies and versions →