j Jessica Leighton - Re: Air Quality at Stuyvesant H.S. Page 2 I
>Date: Thu, 15 Nov 2001 15:15:31 -0500 >To: Charles Mauro <[email protected]> >From: Upmanu Lail <[email protected]> >Subject: Suggestions for >Cc: [email protected]. Steven Chillrud <[email protected]>
»Dear Charles
>Here are my suggestions for a short term plan of action at Stuyvesant. The >primary driver is that we still have limited knowledge of the chemical >composition of the particulates and gases in the area and their potential >effects. The secondary driver is that any short term solution we adopt >also be consistent with a strategy that improves the general indoor air >quality at the school. This is consistent with federal initiatives and >with key objectives stated by the US EPA administrator Whitman. EPA's >guidelines for reducing the incidence of Asthma in Schools through >improved indoor air quality can be found at >(http://www.epa.qov/iaq/schools/. >http://www.epa.gov/iaq/schools/asthma/index.html)
>1) Upgrade of filtration on thexoainair handlers. The intakes for the >main air handlers should be modified to install a three stage filtration >system - a pre-filter, a HEPA Filter and an activated charcoal VOC filter. >lt should be possible to modify the existing intake/ductwork to install a >box with these filters and to perform load tests on the system to ensure >adequate airflow. It is important that all the systems be upgraded in this >manner. Given personnel and materials I see no reason why such an upgrade >could not be performed in 1 working day. >2) Upgrade the filters in all the window unit^to the highest efficiency >units available. For the 1" thickness limit, I understand that there are >several choices available that will dramatically improve the performance >over the filters being used now. These include pleated (multi-layer >bio+activated charcoal) filters as well as electrostatic filters. They may \ >need to be custom cut for the 48x7x1 size, but there are several web sites >that indicate delivery in 2 or 5 days. A local contractor should be able >to execute such an order and recommend the best strategy very quickly. I >see no reason why this entire project for the 300 units cannot be >performed in 1 work week after an order is placed. ________ >3) We need(^artim^/monitoring of soi^ basic indoor air quality >parameters sucTTas'^SrBonMonoxid^-Garbon Dioxide, >Carbon, and particul^es uii a cUfltlTiuous basis at 5 strategic locations in >the school. This is critical given that there is a high aegree oT >recirculation of air and the diesel trucks that are in the neighborhood >and seem to keep idling are a potential source of problems.
>4) We need integrated filter based sampling for particulates and their >chemistry on alternate floors in the school. These readings will indicate >cumulative levels and their is usually a several day delay to get results, >but the results are more accurate than the direct samplers.
>5) We need an appropriately designed and conducted epidemological study >that has short and long term follow up and sampling elements so that we >can detect as many cases as possible developing health effects. A simple >comparative analysis of generic complaints over some historical period is
CITY_21MC100_003036293
NYC-WTC_000321460
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318819
Memo regarding air quality testing discussion at Stuyvesant High School, Nov 25, 2001.
8 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277292
Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.
3 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321960
Letter describing ENVIRON’s evaluation of environmental data around PS 234 facility and sampling history.
2 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317650
Letter informing P.S. 234 PTA of environmental data evaluation results.
2 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318085
Letter detailing ENVIRON's evaluation of environmental data around PS 234 facility and sampling context.
2 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274908
Draft ambient air/dust sampling protocol for asbestos at Stuyvesant High School.
2 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
7 shared non-person entities · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
6 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
6 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324220
Ambient air and dust sampling protocol for Stuyvesant High School; asbestos IAQ.
2 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385863
Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.
2 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
6 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318819
Memo regarding air quality testing discussion at Stuyvesant High School, Nov 25, 2001.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318819
Memo regarding air quality testing discussion at Stuyvesant High School, Nov 25, 2001.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321465
ENVIRON evaluation of environmental data around PS 234, highlighting data collection and sampling context.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243060
Executive summary of DOH BOE indoor air study at SHS; sample results referenced.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321960
Letter describing ENVIRON’s evaluation of environmental data around PS 234 facility and sampling history.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318819
Memo regarding air quality testing discussion at Stuyvesant High School, Nov 25, 2001.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
NYC-WTC_000324220
Ambient air and dust sampling protocol for Stuyvesant High School; asbestos IAQ.
Similar indexed content
Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.
Similar indexed content