NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Stuyvesant High School indoor air study, 2002

Machine-extracted title · confidence 39%

Executive summary of DOH BOE indoor air study at SHS; sample results referenced.

NYC-WTC_000243060–000243095
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Stuyvesant Analysis Final Draft. For Internal NYC DOH Only, 2/8/2002, 10:44 AM

not, in fact, be valid, since both schools enroll students from all NYC boroughs. There are also limitations when comparing the average daily rates between SHS and the non­ science high schools located in lower Manhattan (Murray Bergtram and Seward). For one, it is clear from the attendance rates for Murray Bergtram and Seward in 2000 and 2001, that the student populations are very different (attendance rates are about 10 percentage points below that of the three science high schools). In addition, the raw data indicated that students at Murray Bergtram and Seward High Schools utilize the health offices differently than at SHS and the two other science high schools, i.e., utilizing them for more administrative rather than first aid matters.

Part III: Air Quality Analysis

The correlation between indoor PM 2.5 and HRSET is small, non-significant and negatively correlated. Since the correlation is small, it implies that most of the variation in the daily rate of HRSET complaints is not explained by variation in PM 2.5- The fact that the correlation between PM 2.5 and health complaints is non-significant could be, in part, a result of the small number of observations (n=16). However, with same number of observations there was a strong and significant correlation between indoor and outdoor PM 2.5. The negative correlation would appear to imply that as PM 2.5 increased, there was a tendency for HRSET complaints decrease, a finding completely antithetical to the current understanding of the association between PM 2.5 and HRSET type complaints. There are at least two possible explanations for these results. One, the daily averages of PM 2.5 rarely went above 65 pg/m^ and infrequently above 40 pg/m^ and, therefore, the increase in complaints may not be attributable to poor air quality as estimated by average daily PM 2.5. Secondly, it is also equally plausible that the daily average of all instantaneous measures of PM 2.5 is not a valid measure of PM 2.5 exposure experienced over the school day or of the students seeking care from the Health Office for HRSET complaints.

However, to address some of the inadequacies of using an indoor daily average PM2.5, the number of days in which PM 2.5 increased above 65 pg/m^ was determined. There were three days in which more than one of the indoor instantaneous samples were above the NPAAQS guidelines: on October 22"'’, 35 instantaneous samples were above 65pg/m’; on October 23”*, 107 PM 2.5 samples were above 65pg/m^; and on October 24'*’, 26 samples were above 65pg/m’. However, during the same days, outdoor 24 hour daily average PM 2.5 measurements obtained by the Department of Environmental Conservation at the Borough Manhattan Community College are consistently below 30 pg/m^. During this time the number of headache complaints continued to decline to a daily rate of 0.3 per 1000 on October 24* rising to 1.3 per 1000 on October 25* decreasing to 0.3 per 1000 on October 26*, and increasing to 3.8 per 1000 on October 29*. A comparison of averaged daily HRSET complaints and PM 2.5 levels during this period still do not indicate a clear relationship between increased PM2.5 and an increase in HRSET complaints.

Though the correlation between CO2 and headaches was positive, it was very small (r = 0.1) and not significant, contrasting with the results of the correlation between

19

NYC-WTC_000243078

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243078Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000245464

Permit application unrelated excerpt; contains mayoral report and NYC identifiers; likely overarching documents for school-related permit.

Similar indexed content

NYC-WTC_000277292

Memo reviewing PM2.5 data from Stuyvesant High School air quality testing.

Similar indexed content

NYC-WTC_000138069

Archival folder label for Health Department biweekly reports related to World Trade Center activities from 2000 to 2001.

Similar indexed content

Compare copies and versions →