NYC 9/11 Public Portal Document
Internal DRAFT CPOC Screening Levels May 15, 2002
Crystalline silica - respirable fraction of alpha-quartz
Level Recommended actions Comments
Air level: Limit exposure in order to reduce long The occupational recommended exposure
SOyUg/m’ * term health risks. limit for respirable silica in air is 50
as a time weighted average for an 8
If air samples were not taken, then hour exposure. Any resdiential area which
appropriate air sampling should be exceeds this limit should be cleaned to
conducted to determine if fiber levels prevent exposures at this level.
are elevated in air.
Evaluate conditions in the area
including representativeness of air
samples, asbestos dust levels and
loading.
Take actions to reduce exposures.
- clean area
- resample
- ongoing cleaning
Air level: Evaluate conditions in the area The occupational recommended exposure
5 Lig/nv’ including representativeness of air limit for respirable silica in air is 50
To samples, fibrous glass dust levels and yug/m^ as a time weighted average for an 8
50 yUg/m^ * loading. hour exposure. Adjusting the REL for a
24 hour exposure and a non-worker
Or population, can be done by using an
If air samples were not taken, then uncertainty factor of 10. Any residential
Settled Dust level: appropriate air sampling should be area which exceeds this limit should be
conducted to determine if fiber levels cleaned to prevent exposures at this level.
Above Background are elevated in air.
Settled dust threshold is set at that found
Take actions to reduce exposures. in background, or unaffected areas. In
- clean area this way, no increase in risk due to the
- resample silica dust would be expected.
- ongoing cleaning
Air level: No action required Adjusting the REL for a 24 hour exposure
5 ywg/m^ and a non-worker population, can be done
by using an uncertainty factor of 10.
And
Settled dust threshold is set at that found
Settled Dust level: in background, or unaffected areas. In
s background this way, no increase in risk due to the
silica dust would be expected.
* Silica measured in airborne respirable dust, by NIOSH 7500.
CONFIDENTIAL, CITY_21MC100_003423813
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000242898
OCR can misread numbers and units. Confirm readings against the page image before using them.