Internal DRAFT CPOC Screening Levels May 15, 2002 Crystalline silica - respirable fraction of alpha-quartz Level Recommended actions Comments

Air level: Limit exposure in order to reduce long The occupational recommended exposure SOyUg/m’ * term health risks. limit for respirable silica in air is 50 as a time weighted average for an 8 If air samples were not taken, then hour exposure. Any resdiential area which appropriate air sampling should be exceeds this limit should be cleaned to conducted to determine if fiber levels prevent exposures at this level. are elevated in air.

Evaluate conditions in the area including representativeness of air samples, asbestos dust levels and loading.

Take actions to reduce exposures. - clean area - resample - ongoing cleaning

Air level: Evaluate conditions in the area The occupational recommended exposure 5 Lig/nv’ including representativeness of air limit for respirable silica in air is 50 To samples, fibrous glass dust levels and yug/m^ as a time weighted average for an 8 50 yUg/m^ * loading. hour exposure. Adjusting the REL for a 24 hour exposure and a non-worker Or population, can be done by using an If air samples were not taken, then uncertainty factor of 10. Any residential Settled Dust level: appropriate air sampling should be area which exceeds this limit should be conducted to determine if fiber levels cleaned to prevent exposures at this level. Above Background are elevated in air. Settled dust threshold is set at that found Take actions to reduce exposures. in background, or unaffected areas. In - clean area this way, no increase in risk due to the - resample silica dust would be expected. - ongoing cleaning

Air level: No action required Adjusting the REL for a 24 hour exposure 5 ywg/m^ and a non-worker population, can be done by using an uncertainty factor of 10. And Settled dust threshold is set at that found Settled Dust level: in background, or unaffected areas. In s background this way, no increase in risk due to the silica dust would be expected.

* Silica measured in airborne respirable dust, by NIOSH 7500.

CONFIDENTIAL, CITY_21MC100_003423813 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000242898

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242898Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →