NYC 9/11 Public Portal Document
Minerals in Dust
TLV Tier 1 Tierll Tier in
Gypsum, 10,000 3300 jw/m’ 1000 /z/m’
Calcium
sulfate
Calcite 2000 660 200
Portlandite 10,000 3300 /z/m’ 1000 /z/m’
General approach for air screening levels:
Tier I is set at the TLV reduced by a factor of 10 to account for some of the uncertainty in
predicting when the material may become irritable to sensitive populations.
Tier DI which is intended to be protective over a long-term exposure is further reduced fron Tier
I. The additional uncertainty factor of 10 may address irritant effects after prolonged exposure,
and round the clock exposure, as well as additional consideration of sensitive populations.
Tier n would be the range between Tiers I and HI.
Settled dust;
Compare all minerals to loadings found in the background areas as ug/cm2. Any increased
mineral loading should be addressed as Tier H.
Dust pH should also be dtermined. Any dust exhibiting a pH greater than background or 8.5,
which ever is higher, should be considered an irritant and addressed as Tier H.
CONFIDENTIAL, CITY_21MC1OO_OO3423814
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000242899
OCR can misread numbers and units. Confirm readings against the page image before using them.