NYC 9/11 Public Portal Document
Summary of Asbestos Sampling Results Page 3 of 3
Address: 16 Jay Street Date sampled: December 1, 2001
ASBESTOS DUST TEST RESULTS
In general, the dust and debris samples were examined by two different laboratory methods for
asbestos fibers. Polarized Light Microscopy (PLM) and Transmission Electron Microscopy
(TEM). PLM is used to define asbestos containing material in dust and debris. A material is
considered to be asbestos containing material if it contains more than 1% asbestos using the PLM
method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM
were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does
count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust
samples.
No asbestos fibers were found in the dust samples from the common area or in the two
residences by the PLM laboratory method. No dust was available to sample outside of your
building. TEM analysis also did not detect any asbestos in the indoor dust.
Fibrous materials In dust found by PLM Analysis: Polarized Light Microscopy identifies
asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics),
paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts
the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for
dust samples.
Results of Polarized Light Microscopy (PLM) testing of dust at 16 Jay Street, December 1, 2001
Area Sampled lOutside Common Residence 1 Residence 2 |j
Sample Numbers
ri Dust VA-C-26 VA-Rl-26 VA-R2-26
.vailable
Asbestos fibers (%) o Dust None Detected None Detected None Detected
.vailable
Asbestos in dust as determined by TEM Analysis: TEM analysis was conducted on all dust
samples that showed asbestos content by PLM as less than 1% (if sufficient quantities were
available). TEM analysis is very specific, can detect smaller fibers of asbestos, and is subject to
less interference. This analysis was done to confirm the above PLM findings of no asbestos
found. TEM analysis is not used for regulatory purposes for dust samples.
Results of Transmission Electron Microscopy (TEM) testing of dust at 16 Jay Street,
December 1, 2001
Area Sampled Outside Common Residence 1 esidence 2
Sample Numbers No Dust
VA-C-26 VA-Rl-26 A-R2-26
Available
Asbestos fibers (%) No Dust None Detected None Detected Hone Detected
Available
CONFIDENTIAL, CITY_21MC1OO_OO3423681