Summary of Asbestos Sampling Results Page 2 of 3
Address: 16 Jay Street Date sampled: December 1, 2001
Results of Phase Contrast Microscopy (PCM' testing
"....... of air at 16
...... ' Jay Street, December 1, 2001
Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers A-0-26 A-C-26 A-Rl-26 A-R2-26
Concentration of Fibers in
Air at 16 Jay Street (f/cc)* 0.001 0.004 0.012 <0.001
Concentration of Fibers
(f/cc) in comparison <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003
locations
NYC Re-Occupancy
Standard (f/cc) ** 0.01 0.01 0.01 0.01
* f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air
filter and the volume of air pulled through the filter measured in cubic centimeters of air.
** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work
(Rules of the City of New York, Title 15, Chapter 1)
Asbestos in air as determined by TEM analysis: TEM analysis is vei-y specific and can
distinguish between asbestos and non-asbestos fibers, such as textiles, fiberglass, or cellulose.
This analysis determines if the fibers seen in the PCM analysis are asbestos, or if they are some
other material. TEM analysis was conducted on all air samples that showed more than 0.003 f/cc
in the air by PCM analysis. No asbestos fibers were found in the TEM analysis of the two air
samples in your building where PCM levels exceeded 0.003 f/cc.^
Results of Transmission Electron Microscopy (TEM) testing of air atl6 Jay Street, Dec. 1, 2001
Area Sampled Common Residence 1
Sample Numbers
A-C-26 A-Rl-26
Concentration of Asbestos Fibers in Air at 16
<0.001 < 0.001
Jay Street (f/cc)*
Concentration of All Fibers in Air at <0.001 to 0.003 <0.001 to 0.003
comparison locations (f/cc)________________
|nYC Re-occupancy Standard (f/cc)**
0.01 0.01
* f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter
and the volume of air pulled through the filter measured in cubic centimeters of air.
** New York City Department of Environmental Protection asbestos clearance criteri a for post-abatement work
(Rules of the City of New York, Title 15, Chapter 1)
2 The TEM method employed here, NIOSH 7402, counts fibers of the same size as those detected by PCM analysis.
Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in width.