Asbestos sampling summary, 16 Chambers Street, December 2001

Machine-extracted title · confidence 95%

Summary report of asbestos air and dust sampling results from four locations at 16 Chambers Street on December 1, 2001.

NYC-WTC_000186126–000186128
Page image
Scanned page image, NYC-WTC_000186128
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Simmary ofAsbestos Sampling Results Page 3 of 3 Address: J6 Jay Street Date sampled: December J, 2001

ASBESTOS DUST TEST RESULTS In general, the dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

No asbestos fibers were found in the dust samples from the common area or in the two residences by the PLM laboratory method. No dust was available to sample outside of your building. TEM analysis also did not detect any asbestos in the indoor dust.

Fibrous materials in dust found by PLM Analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust samples.

Results of Polarized Light Microscopy (PLM) testing of dust at 16 Jay Street, December 1, 2001 Area Sampled Outside Common Residence 1 Residence 2 Sample Numbers No Dust VA-C-26 VA-Rl-26 VA-R2-26 Available

Asbestos fibers (%) No Dust None Detected None Detected None Detected Available

Asbestos in dust as determined by TEM Analysis: TEM analysis was conducted on all dust samples that showed asbestos content by PLM as less than 1% (if sufficient quantities were available). TEM analysis is very specific, can detect smaller fibers of asbestos, and is subject to less interference. This analysis was done to confirm the above PLM findings of no asbestos found. TEM analysis is not used for regulatory purposes for dust samples.

Results of Transmission Electron Microscopy (TEM) testing of dust at 16 Jay Street, December 1, 2001

3 Area Sampled Outside Common Residence 1 Residence 2 ====z^====:izz=^=:=^=^==

Sample Numbers No Dust VA-C-26 VA-Rl-26 VA-R2-26 Available

Asbestos fibers (%) No Dust None Detected None Detected None Detected Available

CITY_21MC100_011108675

NYC-WTC_000186128

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186128Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling summary report, Nov 2001

NYC-WTC_000176137

Summary report detailing air and settled dust sampling results from a residential building, including methods for fiber analysis.

Similar indexed content

Compare copies and versions →