NYC 9/11 Public Portal Document
Address: 120 Greenwich Street Date sampled: November 16, 2001
fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust
samples.
Results of Polarized Light Microscopy (PLM) testing of dust at 120 Greenwich St., Nov. 16,
2001
Area Sampled Outside Common Residence 1 Residence 2
No Dust
SA-01-5 VA-Rl-5 VA-R2-5
Sample Numbers Available
Asbestos fibers (%) 3.4 %* No Dust < 1% None Detected
Available
* DOH and the City Department of Environmental Protection (DEP) inspected the building after the sampling was
conducted to determine if further action was warranted. The inspection revealed that no visible dust or debris was
present and no additional action was needed.
Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust
samples that showed asbestos content by PLM as less than 1%. TEM analysis is very specific,
can detect smaller fibers of asbestos and is subject to less interference. This analysis was done to
confirm the PLM findings of no asbestos found. However, TEM analysis is not used for
regulatory purposes for dust samples.
Results of Transmission Electron Microscopy (TEM) testing of dust at 120 Greenwich St.,
Nov 16, 2001_______________________________________________________________
[Area Sampled lOutside I Common Residence 1 Residence 2
[Sample Numbers |No Dust
A-Ol-5 VA-Rl-5 VA-R2-5
LAvailable
Asbestos fibers (%) lot analyzed* [No Dust < 1% < 1%
[Available
* Settled dust samples positive by PLM were not reanalyzed by TEM.
CONFIDENTIAL, CITY_21MC100_003423631
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000242854
OCR can misread numbers and units. Confirm readings against the page image before using them.