NYC 9/11 Public Portal Document
Summary ofAsbestos Sampling Results Page 3 of 3
Address: 120 Greenwich Street Date sampled: November J6, 200J
fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust
samples.
Results of Polarized Light Microscopy (PLM) testing of dust at 120 Greenwich St., Nov. 16,
2001
rea Sampled Outside Common [ResidenceT Residence 2
SA-01-5 No Dust VA-Rl-5 VA-R2-5
iample Numbers Available
Asbestos fibers (%) 3.4 %* No Dust < 1% None Detected
Available
* DOH and the City Department of Environmental Protection (DEP) inspected the building after the sampling was
conducted to determine if further action was warranted. The inspection revealed that no visible dust or debris was
present and no additional action was needed.
Asbestos in dust as determined by TEM analysis: TEM analysis was conducted on all dust
samples that showed asbestos content by PLM as less than 1%. TEM analysis is very specific,
can detect smaller fibers of asbestos and is subject to less interference. This analysis was done to
confirm the PLM findings of no asbestos found. However, TEM analysis is not used for
regulatory purposes for dust samples.
Results of Transmission Electron Microscopy (TEM) testing of dust at 120 Greenwich St.,
Nov 16, 2001
Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers SA-01-5 No Dust VA-Rl-5 VA-R2-5
Available
Asbestos fibers (%) Not analyzed* No Dust < 1% < 1%
Available
* Settled dust samples positive by PLM were not reanalyzed by TEM.
CITY_21MC100_0 04204772
NYC-WTC_000275391
OCR can misread numbers and units. Confirm readings against the page image before using them.