Asbestos sampling results, 120 Greenwich Street, Nov 2001

Machine-extracted title · confidence 58%

Summary of asbestos air testing results at 120 Greenwich Street.

NYC-WTC_000242852–000242854
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Summary of Asbestos Sampling Results Page 2 of 3 Address: 120 Greenwich Street Date sampled: November 16, 2001

the fibers were asbestos. In this building, additional analysis was not v/arranted since the air sampling results were not greater than 0.003 f/cc.

ResultsofPhaseContost^licroscopy(PCM)testingofairaH20G^inwichSt^Noy^l6^001 Area Sampled Outside Outside Common Residence 1 I...-..I .. Residence 2 Sample Numbers A-0-5-2* A-C-5 A-Rl-5 A-R2-5 A-0-5-1

Concentration of Fibers in Air 0.002 0.003 0.002 0.002 <0.001 at 120 Greenwich Street (f/cc)** Concentration of Fibers (f/cc) <0.001 to 0.001 <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 in comparison locations

NYC Re-occupancy 0.01 0.01 0.01 0.01 0.01 Standard (f/cc)*** * Denotes a second air sample in the same location. ** f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. *** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

ASBESTOS DUST TEST RESULTS The dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

Asbestos was found (greater than 1% using the PLM method) in a small amount of dust outside your building, near the front entrance. DOH and the City Department of Environmental Protection (DEP) inspected the building after the sampling was conducted to determine if further action was warranted. The inspection revealed that no visible dust or debris was present and no additional action was needed. Low levels of asbestos were also found (less than 1% using the PLM and TEM methods) in the dust in the residences of your building. However, the concentration of asbestos found in this sample did not warrant the use of an asbestos abatement contractor.

Fibrous materials in dust found by PLM analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the Summary of Asbestos Sampling Results Page 3 of 3

CONFIDENTIAL, CITY_21MC100_003423630 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000242853

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242853Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling summary report, Nov 2001

NYC-WTC_000176137

Summary report detailing air and settled dust sampling results from a residential building, including methods for fiber analysis.

Similar indexed content

Compare copies and versions →