NYC 9/11 Public Portal Document
Page 1 of 3
Summary of Asbestos Sampling Results
120 Greenwich Street, New York, N.Y. 10006
Date sampled: November 16, 2001
Four locations were sampled at your building: inside two private residences, an indoor common
area hallway, and a nearby outdoor area (see tables below for sampling results). One air sample
was collected in each of the four locations and one dust sample was collected outside and from
each of the private residences. No dust was available in the hallway; therefore, no sample was
collected.
Air samples were collected using vacuum pumps to draw air past a filter that was suspended at
the height of a person’s breathing level. Outdoor dust and debris samples were collected by
placing visible material in a container. Indoor dust and debris samples were collected on a filter
by vacuuming surfaces. The collected material was weighed, viewed under a microscope, and/or
chemically processed to determine the types and quantities of substances present. The materials
are being analyzed for fibers such as asbestos, fiberglass, synthetics (e.g. man-made materials
such as nylon and polyester), cellulose (e.g. cotton, paper), silica, and for other minerals and
small particles.
ASBESTOS AIR TEST RESULTS
Results of all of the air samples taken from your building were below the standard set for indoor
air quality - 0.01 fibers per cubic centimeter (f/cc) (see tables below). The highest level of fibers
in the air at your building was 0.003 f/cc. This air level is comparable to the air results from
buildings located above 59* Street, which are not expected to have been impacted by WTC
materials. In the homes above 59* Street, levels of fibers found in the air ranged from less than
0.001 f/cc to 0.003 f/cc. This indicates that the air levels for fibers from your building are similar
to those seen in areas not impacted by the dust from the WTC collapse.
The air samples tested from directly outside and in the lobby of your building were taken during
normal daily activity. The two air samples from the unoccupied apartments were taken after the
dust in the apartment was aggressively “stirred up” to ensure that an accurate sample of particles
would be present. All air samples were examined in a laboratory for fibers using the Phase
Contrast Microscopy (PCM) method.
Airborne fibers as determined by PCM analysis: An air sample is collected by pulling air
through a filter. The filter catches fibers and is sent to a laboratory to determine the number of
fibers in the air. Phase contrast microscopy identifies fibers based on size and shape, but not the
specific type of fiber. Therefore, the fibers seen by PCM include asbestos fibers as well as other
fibers, such as textiles, fiberglass, and cellulose, which might be present in your home. The PCM
analysis assumes that all fibers present were asbestos. Therefore, less hazardous fibers that may
have been present, such as textiles or fiberglass, are counted along with the asbestos fibers, and
the total fiber count is then compared to the asbestos standard. If the results were above 0.003
f/cc using the PCM methodology, additional analysis was performed to determine whether any of
CONFIDENTIAL, CITY_2IMCl00_003423629
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000242852
OCR can misread numbers and units. Confirm readings against the page image before using them.