Allan Goldberg - Nyc-wtc sampling plan v2.doc

was spread throughout the metropolitan area of lower Manhattan following the collapse of the WTC, 2) acquire specific, exposure-based environmental data specifically designed to allow fa a focused human health assessment (both short and long term) for commercial business owners, city workers, and the public who may be exposed to environmental contaminants and asoesuis m dust and debris as they return to their homes and places of business, 3) provide specific chemical and geographic information regarding environmental asbestos contamination if specific cleanup is required. In order to address these concerns with regard to environmental asbestos contamination beyond the immediate vicinity of the WTC collapse, which includes both outdoor and indoor (e.g., offices, apartments) situations, we suggest that the following recommendations be considered and used to refine sampling, analysis, and quality assurance project plans consistent with applicable State and Federal guidance. Of note, information concerning other potentially harmful contaminants (e.g., lead) can also be easily obtained, as indicated, as a compliment to asocstos assessment efforts.

Because human health risk from asbestos is mediated by inhalation exposure, greatest emnnasi:' has been placed on collection and analysis of air samples. To date, most air samples at locations surrounding the WTC have been collected using stationary air monitors and the concentration or' fibers has been estimated using Phase Constrast and/or Transmission Electron Microscopy (TEM). However, there are issues which exist with regard to both the collection technique (stationary air monitors) and the analytical technique (PCM/TEM).

With regard to the stationary air monitor sampling method, the potential issue is that, in a I, location where asbestos fibers are present in a source such a.s dust or debris, some types of human activities may tend to “kick-up” asbe.sto.s fibers into the air, resulting in an increase m asbesto,s fiber concentration in the breathing zone of the person engaged in the activity, i )ne study has shown that asbestos concentrations in soil even well below 1% (i.e., 0.001%) by volume can generate hazardous personal airborne asbestos exposures depending on the activity (Addison 1988). Stationary air monitors are useful and appropriate for assessing the "passive" exposures of people in area.s (i.e., apartments, offices) who are not engaged in dust generating activities (e..g., watching TV, sitting at a desk), but may greatly underestimate (as much a.s 11)() to 1000 fold) exposure.s of the people directly engaged m activities which can generate dust (e.u. house or office cleaning work). Tliei efin-e, the first objective of this sainpliii!^ ‘^jfai't ’■'i to ineosiii e asbestos levels in the breathiii!' t.oiie qf'iiKlividiials eii};agetl in routine and sneeia/ activities in businesses, apartnients and near the areas impacted by the collapse of the f l'TC. and Io compare those measurements to data collected from co-located (or near-by) stationary air monitors. This information will be helpful in deciding what type of air sampling method i.s needed to evaluate risks to individuals engaged in both routine and special activuie.s in businesses and/or apartments. t

With regard to the analytical technique, the issue i.s that air samples have historically been analyzed for asbestos using Phase Contrast Light Microscopy (PCM), and the EPA current slope factor for quantifying lung cancer risk from asbestos in air is expressed in units of risk per I’CM fiber per cc of air (USEPA 2000a). Thus, even though it is widely recognized that f EM analyses are more accurate and more powerful than PCM analyses, measurements of asbestos

NYC-WTC_000241750

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241750Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →