WTC, 2) acquire specific, exposure-based environmental data specifically designed to allow for a focused human health assessment (both short and long term) for commercial business owners, city workers, and the public who may be exposed to environmental contaminants and asbestos in dust and debris as they return to their homes and places of business, 3) provide specific chemical and geographic information regarding environmental asbestos contamination if specific cleanup is required. In order to address these concerns with regard to environmental asbestos contamination beyond the immediate vicinity of the WTC collapse, which includes both outdoor and indoor (e.g., offices, apartments) situations, we suggest that the following recommendations be considered and used to refine sampling, analysis, and quality assurance project plans consistent with applicable State and Eederal guidance. Of note, information concerning other potentially harmful contaminants (e.g., lead) can also be easily obtained, as indicated, as a compliment to asbestos assessment efforts.

Because human health risk from asbestos is mediated by inhalation exposure, greatest emphasis has been placed on collection and analysis of air samples. To date, most air samples at locations surrounding the WTC have been collected using stationary air monitors and the concentration of fibers has been estimated using Phase Constrast and/or Transmission Electron Microscopy (TEM). However, there are issues which exist with regard to both the collection technique (stationary air monitors) and the analytical technique (PCM/TEM).

With regard to the stationary air monitor sampling method, the potential issue is that, in a location where asbestos fibers are present in a source such as dust or debris, some types of human activities may tend to “kick-up” asbestos fibers into the air, resulting in an increase in asbestos fiber concentration in the breathing zone of the person engaged in the activity. One study has shown that asbestos concentrations in soil even well below 1% (i.e., 0.001%) by volume can generate hazardous personal airborne asbestos exposures depending on the activity (Addison 1988). Stationary air monitors are useful and appropriate for assessing the "passive" exposures of people in areas (i.e., apartments, offices) who are not engaged in dust generating activities (e..g., watching TV, sitting at a desk), but may greatly underestimate (as much as 100 to 1000 fold) exposures of the people directly engaged in activities which can generate dust (e.g, house or office cleaning work). Therefore, the first objective of this sampling effort is to measure asbestos levels in the breathing zone of individuals engaged in routine and special activities in businesses, apartments and near the areas impacted by the collapse of the WTC, and to compare those measurements to data collectedfrom co-located (or near-by) stationary air monitors. This inforaiation will be helpful in deciding what type of air sampling method is needed to evaluate risks to individuals engaged in both routine and special activities in businesses and/or apartments.

With regard to the analytical technique, the issue is that air samples have historically been analyzed for asbestos using Phase Contrast Eight Microscopy (PCM), and the EPA current slope factor for quantifying lung cancer risk from asbestos in air is expressed in units of risk per PCM fiber per cc of air (USEPA 2000a). Thus, even though it is widely recognized that TEM analyses are more accurate and more powerful than PCM analyses, measurements of asbestos concentration based on TEM are difficult to convert to an equivalent concentration by PCM (this is refened to as PCM equivalents, or PCME). Thus, the second objective of this sampling

CITY_21MC100_006455389

NYC-WTC_000454768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →