NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
19 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Final NYC-WTC sampling plan documenting fiber exposure assessments.
NYC-WTC_000241981–000242016OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
p Jeanine Prudhomme - Nyc-wtc sampling plan y2.doc Page 61
was spread throughout the metropohtan area of lower Manhattan following the collapse of the WTC, 2) acquire specific, exposure-based environmental data specifically designed to allow for a focused human health assessment (both short and long term) for commercial business owners, city workers, and the public who may be exposed to environmental contaminants and asbestos in dust and debris as they return to their homes and places of business, 3) provide specific chemical and geographic information regarding environmental asbestos contamination if specific cleanup is required. In order to address these concerns with regard to environmental asbestos contamination beyond the immediate vicinity of the WTC collapse, which includes both outdoor and indoor (e.g., oflQces, apartments) situations, we suggest that the following recommendations be considered and used to refine sampling, analysis, and quality assurance project plans consistent with applicable State and Federal guidance. Of note, information concerning other potentially harmful contaminants (e.g., lead) can also be easily obtained, as indicated, as a compliment to asbestos assessment efforts.
Because human health risk from asbestos is mediated by inhalation exposure, greatest emphasis has been placed on collection and analysis of air samples. To date, most air samples at locations surrounding the WTC have been collected using stationary air monitors and the concentration of fibers has been estimated using Phase Constrast and/or Transmission Electron Microscopy (TEM). However, there are issues which exist with regard to both the collection technique (stationary air monitors) and the analytical technique (PCM/TEM).
With regard to the stationary air monitor sampling method, the potential issue is that, in a location where asbestos fibers are present in a source such as dust or debris, some types of human activities may tend to “kick-up” asbestos fibers into the air, resulting in an increase in asbestos fiber concentration in the breathing zone of the person engaged in the activity. One study has shown that asbestos concentrations in soil even well below 1% (i.e., 0.001%) by volume can generate hazardous personal airborne asbestos exposures depending on the activity (Addison 1988). Stationary air monitors are useful and appropriate for assessing the "passive" exposures of people in areas (i.e., apartments, offices) who are not engaged in dust generating activities (e..g., watching TV, sitting at a desk), but may greatly underestimate (as much as 100 to 1000 fold) exposures of the people directly engaged in activities which can generate dust (e.g, house or office cleaning work). Therefore, thefirst objective of this sampling effort is to measure asbestos levels in the breathing zone of individuals engaged in routine and special activities in businesses, apartments and near the areas impacted by the collapse of the WTC, and to compare those measurements to data collected from co-located (or near-by) stationary air monitors. This information will be helpful in deciding what type of air sampling method is needed to evaluate risks to individuals engaged in both routine and special activities in businesses and/or apartments.
With regard to the analytical technique, the issue is that air samples have historically been analyzed for asbestos using Phase Contrast Light Microscopy (PCM), and the EPA current slope factor for quantifying lung cancer risk from asbestos in air is expressed in units of risk per PCM fiber per cc of air (USEPA 2000a). Thus, even though it is widely recognized that TEM analyses are more accurate and more powerful than PCM analyses, measurements of asbestos I
NYC-WTC_000241986
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
19 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241745
Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.
19 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
20 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
19 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418628
Draft NYC DOH environmental monitoring document relating to WTC collapse exposure fibers.
19 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
8 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282437
Background and plan for on-site asbestos monitoring during interior cleaning at 114 Liberty Street.
6 shared non-person entities · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155422
Distribution of updated monitoring specifications and related documents for the 114 Liberty Street project.
6 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similar indexed content
NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similar indexed content
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similar indexed content
NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
Similar indexed content
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similar indexed content