j; Allan Goldberg - Nyc-wtc sampling plan v2.cioc Page 22

bulk dust sample will be collected within each building. This sample will normally be collected from the windowsills, walls, or ventilating system of the building, depending on the location of the dust or debris. In the case of larger buildings or buildings which have been renovatea, it may be necessary to collect more than one dust sample to get a more representative sampling of the building.

All bulk dust samples will be collected in accordance with NIOSH Method 9002, Asbestos (bulk) by TEM. There will be no modifications to this method for the purposes of collecting bulk samples for this project.

The samples will be collected by placing approximately 2 ounces of dust into a plastic zip-top bag. The bag will then be placed into a second plastic zip-top bag. All samples will be double bagged The bulk material will preferably be collected from several locations in order to obtain a homogenized sample of the material. Sampling personnel will wear disposable nitrile gloves while sampling the dust. A new pair of gloves will be donned prior to each sample being collected. Sampling personnel will also wear appropriate respiratory protection at all times while collecting bulk dust samples.

Ail borne Dust Monitoring

Airborne dust levels will be measured using a real-time aerosol monitor in accord with the method contained within SOP EPA-LlBBY-03. In general, one aerosol monitor will be located in close proximity to the stationary air monitor, and another will be located in close proximity to the person engaged in the activity.

Deviations from SOPs

Every reasonable effort will be made to adhere strictly to specified SOP.s for sample and data collection. Where deviation from an SOP is unavoidable, documentation of the deviation and lu; potential impact on the outcome of the data collection effort will be clearly indicated in field notes and subsequent reports. I B3. SAMPLE DOCUMENTATION, HAND LING AND CUSTODY REQU I REM ENT h Documentation of sample collection, handling, and shipment will include completion of chain-of-custody forms in the field, use of field maps and field data forms, and entry of data into a field logbook. Each sample will be properly labeled with the a unique sample identifier. A chain-oficustody form shall accompany every shipment of samples to the analytical laboratory. The purpose of the chain-of-custody form is to establish the documentation necessary lo trace possession from the time of collection to final disposal.

field Log Book

Each sampling team will maintain a field log book in which the following information is

I.

h

NYC-WTC_000241766

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241766Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →