NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

NYC-WTC sampling plan final draft, 2001

Machine-extracted title · confidence 45%

Final NYC-WTC sampling plan documenting fiber exposure assessments.

NYC-WTC_000241981–000242016
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

activity do not become overloaded with particulate material. This is not a concern for air filters collected during routine apartment activities, and is not likely to be of concern for filters collected during active cleaning activities (sweeping, dusting), or during restoration / remediation (unless the weather is very dry). The chief concern is for personal air samples collected during simulated apartment restoration activities that involve active disturbance of visible dust. For this scenario, it may be necessary to use a low flow (e.g., 0.5 L/min) and to collect several sequential samples during the activity to avoid filter overload.

Dust Samples

As noted above, dust samples will be collected at each of the eight apartments in which routine and active cleaning activities are investigated. All dust samples for evaluation of asbestos content will be collected using a Microvac method as detailed in SOP ASTM 5755-95, as modified for this project.

Ornamenital or Vegetable Garden Soil Samples (if applicable)

All garden soil samples will be collected in accordance with SOP CDM SOP 1-3. After collection, each soil sample will be prepared in accordance with SOP ISSI-Libby-01.

Dust Samples

Bulk dust sampling locations will be determined based on the amount of visible overburden within each building and the location of dust contamination within the building. At least one bulk dust sample will be collected within each building. This sample will normally be collected from the windowsills, walls, or ventilating system of the building, depending on the location of the dust or debris. In the case of larger buildings or buildings which have been renovated, it may be necessary to collect more than one dust sample to get a more representative sampling of the building.

All bulk dust samples will be collected in accordance with NIOSH Method 9002, Asbestos (bulk) by TEM. There will be no modifications to this method for the purposes of collecting bulk samples for this project.

The samples will be collected by placing approximately 2 ounces of dust into a plastic zip-top bag. The bag will then be placed into a second plastic zip-top bag. All samples will be double bagged The bulk material will preferably be collected from several locations in order to obtain a homogenized sample of the material. Sampling personnel will wear disposable nitrile gloves while sampling the dust. A new pair of gloves will be donned prior to each sample being collected. Sampling personnel will also wear appropriate respiratory protection at all times while collecting bulk dust samples.

Airborne Dust Monitoring

Airborne dust levels will be measured using a real-time aerosol monitor in accord with the

NYC-WTC_000242002

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242002Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →