summarized in Table B-1. Flow charts tracing the path and handling of the air samples collected in Scenarios 1-4 are shown in Figures B-1 to B-4, respectively.

Bib. Housing Characteristics

For Sieenarios 1, 2, and 3, potentially relevant attributes of the apartment or ouilding where samples^Hte collected will be recorded using the Housing Attributes fkld data sheet provided in Appendix A/Hn addition, videotape will be used to record the appearance of the structure (inside and out), and to rebated qualitative information on airflow direption and rate (as assessed using a smoke generator). I hnbdata collection and recording will be done prior to the initiation of any environmental sampling activities. X

Bic. Documentation of Activities

Scenario 1

Each volunteer who participates in^enario 1 will befn^ructed that they should remain indoors to the maximum extent possible^^d that they should engkge in all normal activities except active cleaning. Each time that a project team member come^Ho the apartment to check or change pumps, the activities^f the resident during the preceding lime interval will be recorded on an activity log (see Appendix D). Videotaping of the resident durmgroutine activities will not usually be performed, but any special activities that are judged to be afikely source of increased exposureXo airborne asbestos fibers may be videotaped to documcnMhe activity.

Scenarios X3, and 4

The ^ivities specified in Scenario 2 (active cleaning). Scenario 3 (simulated restoration)\^d Sc^ario 4 (site restoration/remediation) will all be documented using video exposure monitoring.

B2. SAMPLING METHODS REQUIREMENTS

Air Samples

All air samples (both personal air and fixed station) to be analyzed for asbestos will be collected by drawing air through a cellulose acetate filter at the flow rates and times specified above. All samples collected using a high-volume pump will employ filters that have pores that are 0.45 um in diameter. For personal air samples using a low volume pump, filters with pores that are 0.8 um in diameter may be used, since this decreases back-pressure and increases flow rate without significant impact on the quality of the sample. The details of the air sampling method for personal and stationary air monitors are provided in SOP EPA-LIBBY 01.

Because some of the activities being investigated in this project may generate significant concentrations of airborne dust, it is important to ensure that air filters collected during the

NYC-WTC_000242001

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242001Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →