Allan Goldberg - Nyc-wtc sampling plan v2.doc Page2l!

'I I

!

Scenarios 2, 3, and 4

The activities specified in Scenario 2 (active cleaning), Scenario 3 (simulated restoration), and Scenario 4 (site restoration/remediation) will all be documented using video exposure monitoring.

B2. SAMPLING METHODS REQUIREMENTS

Air Samples

All air samples (both personal air and fixed station) to be analyzed for asbestos will be collected by drawing air through a cellulose acetate filter at the flow rates and time.s specified above. All sample.s collected using a high-volume pump will employ filters that have pore.s that are u.-rf uni in diameter. For personal air samples using a low volume pump, filters with pores that are O.S um in diameter may be used, since this decreases back-pressure and increases flow rate without significant impact on the quality of the sample. The details of the air sampling method for personal and stationary air monitors are provided in SOP EPA-LIBBY 01.

Because some of the activities being investigated in this project may generate significant concentrations of airborne dust, it is important to ensure that air filters collected during the activity do not become overloaded with particulate material. This is not a concern for air filters collected during routine apartment activities, and is not likely to be of concern for filters collected during active cleaning activities (sweeping, dusting), or during restoration / remediation (unless the weather is veiy dry). The chief concern is for personal air samples collected during simulated apartment restoration activities that involve active disturbance of visible dust, for this scenario, it may be necessary to use a low flow (e.g., 0.5 L/min) and to collect several sequential samples during the activity to avoid filter overload.

Dust Samples

A.S noted above, dust samples will be collected at each of the eight apartments in which routine f and active cleaning activities are investigated. All dust samples for evaluation of asbestos I content will be collected using a Microvac method as detailed in SOP ASTM 5755-05. as modified for this project.

Ornamental or Vegetable Garden Soil Samples (inapplicable) I' |. All garden soil samples will be collected in accordance with SOP CDM SOP 1-3. Aller 1 collection, each soil sample will be prepared in accordance with SOP ISSl-Libby-OI. I

Dust Samples

Bulk dust sampling locations will be determined based on the amount of visible overburden li within each building and the location of dust contamination within the building. At least one

NYC-WTC_000241765

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241765Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →