NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, H.S. site, 2001

Machine-extracted title · confidence 37%

TEM asbestos analysis for H.S. project; 5543; received 09/21/01.

NYC-WTC_000241260
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Streen New York, New York 10010

New York City Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED WLAP Lab Code # 118 7 Long Island City, NY 11101 Report Date: 09/21/01

ASBESTOS fiber ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM; With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, DPA Federal Register [40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample IdencificaLion Analysis Parameters

Project/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.; 554? 593C3 11th Floor Mechanical Space Date Received; Q9/21/C1 Grid Openings Analyzed:__4

Project Sample No.; NSHS-L3.M5-9/21 -17 A-verage Grid Opening: 106 . PC um

Air Volume Total Area Analyzed : 0;045C^mnu

Filter Type: MCE 25 mm diam.,, Pore Size: 0.45 um Analytical Sensitivity Effective Aree. :385 miT^ C.0047 s,’

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Scruct/cc ncrm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.OOOC 0

Amphibole Tisbestos 0 0 0 0 0 0 0.0 0.OOOC 0

Ambiguous 0 0 0 0 0 0 0 . 0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0 , 0 0 . 0000 0

Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0 . 0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/'SAED) : None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003433349 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241260

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241260Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293314

TEM asbestos fiber analysis for New Stuyvesant High School, received 09/21/01.

Similar indexed content

NYC-WTC_000188615

Technical report presenting transmission electron microscopy data for asbestos fiber identification on air samples.

Similar indexed content

NYC-WTC_000270225

TEM asbestos analysis with SAED/EDS and 9/21/01 dates for New Stuyvesant High School.

Similar indexed content

Compare copies and versions →