TEM analysis, NSHS NSHS-llMS-9/21-10

Machine-extracted title · confidence 50%

TEM analysis parameters and results for NSHS sample NSHS-llMS-9/21-10.

NYC-WTC_000270218
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 New York City Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island,City, NY 11101 Report Date.: 09/21./01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763)_, Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Proj ect/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: SS43 - ' 59296 lich Floor Mechanical Space Date Received: 09/21/01 Grid Openings Analyzed:__ 4

Project Sample No.; HSHS-llMS-9/21-10 Average Grid Opening: 106.00 urn

Air Volume; 1820 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam.. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 38 5 tnm2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single . Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >»5uni Struct/mm2 Struct/cc nQm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

-Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 O.QOOO 0 Non-Asbestos . 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED) None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified 'for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099183

NYC-WTC_000270218

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270218Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270598

TEM asbestos fiber analysis report for New York City building site; AHERA method, 10/20/01.

Similar indexed content

Compare copies and versions →