NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, H.S. site, 2001

Machine-extracted title · confidence 40%

TEM asbestos fiber analysis for H.S. project, received Sep 21, 2001; SAED/EDS used.

NYC-WTC_000241256
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

New York City Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 09/21/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With FiDer Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: MERA Final Rule, EDA Federal Register (40 CFR, Part 7S3), Vol. 52, No. 210, October 30, 1987

Sample Identification Analyses Parameters

Project/Site: New Stu\wesant H.5., 345 Chambers St., NY, NY TEM Sample No.: 5543 59299 11th Floor Mechanical Space Date Received: 09/21/01 Grid Openings Analysed; 4

Project Sample No.: NSHS-1LMS-9/21-13 Average Grid Opening

Air Volunie : 1910 liters Total Area Analyzed :0;045£mrn2

Filter Type: MCE 25 mm diam., Pore Si n . 45 um Analytical Sensitivity Effective Area; 385 mrT^ 0.004~ s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >«5um Struct/rnrri2 Struct/cc ncTm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 o.ocoo 0

Ambiguous 0 c 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-.Asbestos 0 C 0 0 0 0 O.C 0.0000 N/A No Identification 0 C 0 0 0 0 O.C O.OOOC N/A

Totals (All Structures) 0 0 O.C O.OOOC N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003433345 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000241256

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000241256Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270586

TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

Compare copies and versions →