Analytical lab reports: PCDDs & PCDFs, NYC-WTC

Machine-extracted title · confidence 27%

Attachment page of confidential analytical lab reports for city WTC samples.

NYC-WTC_000240913–000240928
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services. Inc. 170D Elm Street. Suite 2DC! ..race Analytical" Minneapolis, MN 55414 Phone: 612.S07.170D wwv.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.507.5444

Pf^OJECT: PCDD/PCDF ANALYSES DATE: January 22, 2002

PAGE: 4 REPORT NO: 02-1052821

PCDD/PCDF Quantification and ------------------------- - Calculations -----------------------------------

' ’ The PCDD/PCDF isomers were quantified by comparison of their responses to the responses of the labeled internal standards. Relative response factors were calculated from analyses of standard mixtures containing representatives of each of the PCDD/PCDF congener classes at five concentration levels, and each of the internal standards at one concentration level, as shown in Table 4-. The PCDD/PCDF response factors were calculated by comparing the sum of the responses from the two ion masses monitored for each chlorine congener class to the sum of the responses from tnsi two ion masses of the corresponding isotopically labeled internal standard. The formula for the response factor calculation is: ri Cl An X Qis Rf - Ais X Qn

where:

' Rf = Response factor fl An = Sum of integrated areas for native isomer i ’ Qis Quantity of labeled internal standard Ais - Sum of integrated areas for labeled internal standard ' . Qn = Quantity of native isomer

The levels of PCDD/PCDF in each sample were quantified using the following equation:

An x Qis C = Ais X W X Rf ri where:

r ■! C == Concentration of target isomer or congener class Uj An - Sum of integrated areas for the target isomer or congener class Qis = Quantity of labeled internal standard added to the sample - Ais =: Sum of integrated areas for the labeled internal standard W = Sample amount Rf = Response factor

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

/ndac-i CONFIDENTIAL, CITY_21MC100_003432821 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240918

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240918Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000240837

Series of Pace Analytical lab pages including C/F levels; NYC-WTC dataset.

Similar indexed content

Compare copies and versions →