Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 f^ceAnalyticaT Minneapolis, MN 55414 Phone: 612.607.1700 -.-.Tj www.pacelabs.eom REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

I PROJECT: PCDD/PCDF ANALYSES DATE: January 9, 2002

PAGE: 4 REPORT NO: 01-1052541

i PCDD/PCDF Quantificafion and Calculations

iJS The PCDD/PCDE isomers were quantified by comparison of their responses to the responses of the labeled interinaT standards. Relative response factors were calculated from analyses of standard B mixture^containing representatives of each of the PCDD/PCDF congener classes at five conceriSration levels, and each of the internal standards at one concentration level, as shown in Tab1^4. The PCDD/PCDF response factors were calculated by comparing the sum of the ^^^sponses from the two ion masses monitored for each chlorine congener class to the sum of the responses from the two ion masses of the corresponding isotopically labeled internal standard. The formula for the response factor calculation is:

An X Qis Rf = Ais X Qn

where: •

Rf = Response factor An = Sum of integrated areas for native isomer Qis = Quantity of labeled internal standard Ais = Sum of integrated areas for labeled internal standard Qn = Quantity of native isomer

The levels of PCDD/PCDF in each sample were quantified using the following equation:

An X Qis C = Ais X W X Rf n where: M C = Concentration of target isomer or congener class An = Sum of integrated areas for the target isomer or congener class Qis = Quantity of labeled internal standard added to the sample Ais = Sum of integrated areas for the labeled internal standard ’ W = Sample amount Rf = Response factor

J

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC100_003432722 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240841

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240841Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000312330

Attachment with PCDD/PCDF analysis identifiers for NYC-WTC samples.

Similar indexed content

Compare copies and versions →