Pace Analytical Services, Inc. T70D Elm Street. Suite 200 'ace Aaalytical" Minneapolis MN 55414 Phons: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444 J PROJECT: PCPD/PCDF ANALYSES DATE: January 22, 2002

PAGE: 3 REPORT NO: 02-1052821

■ * PCDD/PCDF Analyses ICont.l

-Is The mass spectromerter was operated in the electron impact ionization mode at a mass resolution ■ of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve , most interferences, such as PCBs, thus providing the highest level of confidence that the detected levels of PCDD/PCDF were not false positives resulting from interferences. Typical operating parameters for the HFIGC/HRMS analyses are summarized in Table 2.

yi The data were acquired by selected-ion-recording (SIR) using groups of ion masses similar to those described in USEPA Method 8290. The five groups corresponded to the tetrachlorinated through octachlorinated congener classes. Each group contained two ion masses for the PCDDs, two ion I masses for the PCDFs, the corresponding ion masses from the two isotopically labeled internal standards, and tne ion mass characteristic of the polychlorinated diphenylether (PCDE) which, if i present, could cause false responses in the dibenzofuran channels.

Each group of ion masses also contained a lock mass which was used by the data system to automatically correct the mass focus of the instrument. The data system determined the centroid , of the lock mass during each data acquisition cycle and corrected the mass focus of the analyte and internal standard ion masses to assure that the centers of the mass peaks were being 1 monitored. r J

The criteria used tc judge positive responses for a PCDD/PCDF isomer included: ■ 1

Simultaneous response at both ion masses of the PCDD or PCDF Signal-to-noise ratio equal to or greater than 2.5:1.0 for both ion masses Chlorine isotope ratio within 15% of the theoretical value * Chromatographic retention time within -F/- 2 seconds of the expected retention time Chromatographic retention times within elution windows determined from analyses of j standard mixtures i * Absence of simultaneous response in the PCDF and PCDPE ion traces

A A list of the exact ion masses monitored for the determination of PCDD/PCDF isomers and the " PCDE interferences is presented in Table 3. Also included are the theoretical chlorine isotope ratios for the ten congenesr classes.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc,

rtieiac' CONFIDENTIAL, CITY_21MC100_003432820 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240917

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240917Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000240837

Series of Pace Analytical lab pages including C/F levels; NYC-WTC dataset.

Similar indexed content

Compare copies and versions →