Pace Analytical Services, Inc. 1700 Elrr- Street. Suite 200 ’^ceAnalyticar Minneaoolis MN 55414 Phone: 612.607.1700 wmv.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fa.>:: 612.507.6444

PROJECT; F’CPD/PCDF ANALYSES DATE: January 22, 2002

PAGE: 2 REPORT NO: 02-1052821

3 ■

PCDD/PCDF Analyte Enrichment --------------------------- ---------------------- ’ The exTraction procedure often removes a variety of compounds, in addition to the PCDDs and ,, PCDFs, from the SEimple matrix. Some of these compounds can directly interfere with the analyses ’ while others can overload the capillary column causing degradation in chromatographic resolution ' ' or sensitivity. The analyte enrichment steps described below are used to remove interferences .._ from the extracts. - ■

Each extract was diluted to 100 mL with hexane, transferred to a separatory funnel, and washed with 1N sodium hydroxide, concentrated sulfuric acid, and aqueous sodium chloride (5% w/v) as ‘ needed. The hexane; extract was quantitatively transferred to a liquid chromatography column containing alternating layers of silica gel, 40% concentrated sulfuric acid on silica gel, and 33% 1 N sodium hydroxide on silica gel. The column was eluted with 90 mL of hexane and the entire ( eluate was collected and concentrated, under ambient conditions, to a volume of 1 mL.

Each extract was then fractionated on a liquid chromatography column containing 4 g of activated : alumina. The column was eluted with 20 mL of hexane followed by 15 mL of 60% methylene chloride/hexane. The 60% methylene chloride/hexane fraction was concentrated to 1 mL under a 1 stream of dry nitrogen and applied to the top of a chromatography column containing 1 g of 5% 3 AX-21 activated carbon in silica gel. The column was eluted with two 2-mL portions of hexane, 2 mL of cyclohexane/methylene chloride (50:50 v/v) and cyclohexane/methanol/toluene (75:20:5 1 v/v) in the forwarc direction, and then with toluene in the reverse direction. The toluene fraction L was collected, concentrated, spiked with recovery standards (1,2,3,4-TCDD-’^C,2 and 1,2,3,7,8,9- HxCDD-^-Ci2) and taken to a final volume of 20 uL.

PCDD/PCDF Analyses

Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a •N Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced directly into the ion source of the mass spectrometer, thus providing the highest possible sensitivity while minimizing degradation of the chromatographic resolution.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

nelac CONFIDENTIAL, CITY_21MC100_003432819

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000240916

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000240916Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000240837

Series of Pace Analytical lab pages including C/F levels; NYC-WTC dataset.

Similar indexed content

Compare copies and versions →