NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
j' Minneapolis, MN 55414
□ ^ceAnalvticar__________ Method 8290 Analysis Results
TbI: 612-607-1700
Fax:612-607-6444
'•■■I Client - ATC
Client's Sample ID ATC-1220-STY-DX3
Lab Sample ID 103234027
Filename F11228B_15
i Injected By
Total Amount Extracted
% Moisture
BAL
1 m2
NA
Matrix
Dilution
WIPE .
NA
I Dry Weight Extracted
ICAL Date
CCal Filename(s)
NA
11/19/2001
F11228B_01 & F11228B_16
Collected
Received
Extracted
12/20/2001
12/21/2001
12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 08:59
Native Cone EMPC LRL Internal ng's Percent
a Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0068 0.0020 J 2,3.7,8-TCDF-13C 2.00 64
3 TotalTCDF .
2,3,7,8-TCDD
0.1800_
0.0025
0.0020
0.0020 'J
2,3,7.8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
2.00
2.00
79
67
66
a Total TCDD
1,2,3,7,8-PeCDF
2,3,4,7,8-PeCDF
0.2400
ND
0.0120
0.0020
0.0100
0.0100 J
1,2,3,7,8-PeCDD-13C
1,2,3,4.7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2.3,4,6.7.8-HxCDF-13C
2.00
2.00
2.00
2.00
81
85
74
79
Total PeCDF 0.0990 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 79
I 1,2,3,7,8-PeCDD
Total PeCDD
ND
0.1800
0.0100
0.0100
1,2.3.4.7,8-HxCDD-13C
1,2,3,6,7,8-HxCDD-13C
1,2,3,4,6,7,8-HpCDF-13C
2.00
2.00
2.00
110
83
82
1,2,3,4.7,8,9-HpCDF-13C 2.00 79
i 1.2,3,4,7,8-HxCDF
1,2,3,6,7,8-HxCDF
2.3,4,6,7,8-HxCDF
0.0130
ND
0.0150
0.0100 J
0.0100
0.0100 J
1,2,3,4,6.7.8-HpCDD-13C
OCDD-13C
2.00
4.00
96
69
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
3 Total HxCDF
1,2,3,4,7,8-HxCDD
0.0880
ND
0.0100
0.0100
1,2.3.7.8,9-HxCDD-13C
2,3.7.8-TCDD-37CI4
2.00
0.20
NA
77
1,2,3,6,7,8-HxCDD 0.0130 0.0100 J
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.2400 0.0100
1,2,3,4,6,7,8-HpCDF 0.0530 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.015 ng/m2
Total HpCDF 0.0530 0.0100 (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD 0.0920 0.0100
I Total HpCDD
OCDF
0.1700
0.0660
0.0100
0.0200 J
a OCDD 0.6500 0.0200
Cone = Concentration (Totals include 2,3,7,8-substitiJted isomers)
LRL = Lower Reporting Limit
I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blarik level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 01-1052541
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003432738
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240857
OCR can misread numbers and units. Confirm readings against the page image before using them.